HP DL560 HP ProLiant DL560 Server User Guide - Page 101

Servers Troubleshooting Guide, Check the monitor, if you have a monitor installed, for the following

Page 101 highlights

Server Specific Troubleshooting 101 − Check the status using the power supply LEDs on the rear panel ("Rear Panel LEDs and Buttons" on page 12). − Refer to the Servers Troubleshooting Guide for details on checking power supply operation. 4. If the system does not complete POST or start loading an operating system, refer to the Servers Troubleshooting Guide for information on general loose connections. 5. If the server is rebooting repeatedly, the system may be experiencing a problem that initiates an ASR-2 reboot. Refer to the Servers Troubleshooting Guide for information on ASR-2 and system short circuiting. 6. Restart the server. 7. Check the server for the following normal power-up sequence to be sure that the system meets the minimal hardware requirements and is powered up during normal operations: a. The front panel system power LED turns from standby (amber) to on (solid green). b. The fans start up. 8. Check the monitor, if you have a monitor installed, for the following messages that indicate the system meets the minimal hardware requirements and is powered up during normal operations: − ProLiant logo − Memory test − ROM information − Copyright information − Processor initialization − Array controller initialization − SCSI devices − PXE initialization

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

Server Specific Troubleshooting
101
Check the status using the power supply LEDs on the rear panel ("Rear
Panel LEDs and Buttons" on page 12).
Refer to the
Servers Troubleshooting Guide
for details on checking
power supply operation.
4.
If the system does not complete POST or start loading an operating system,
refer to the
Servers Troubleshooting Guide
for information on general loose
connections.
5.
If the server is rebooting repeatedly, the system may be experiencing a
problem that initiates an ASR-2 reboot.
Refer to the
Servers Troubleshooting Guide
for information on ASR-2 and
system short circuiting.
6. Restart the server.
7.
Check the server for the following normal power-up sequence to be sure that
the system meets the minimal hardware requirements and is powered up
during normal operations:
a.
The front panel system power LED turns from standby (amber) to on
(solid green).
b.
The fans start up.
8.
Check the monitor, if you have a monitor installed, for the following
messages that indicate the system meets the minimal hardware requirements
and is powered up during normal operations:
ProLiant logo
Memory test
ROM information
Copyright information
Processor initialization
Array controller initialization
SCSI devices
PXE initialization