HP DL560 HP ProLiant DL560 Server User Guide - Page 24

Hot-Plug SCSI Hard Drive LED Combinations

Page 24 highlights

24 HP ProLiant DL560 Server User Guide Hot-Plug SCSI Hard Drive LED Combinations Activity LED On On Flashing Off Off Off On or flashing Online LED Off Flashing Flashing Off Off On On Fault LED Off Off Flashing Off On Off Off Means Do not remove the drive. Removing a drive during this process causes data loss. The drive is being accessed and is not configured as part of an array. Do not remove the drive. Removing a drive during this process causes data loss. The drive is rebuilding or undergoing capacity expansion. Do not remove the drive. Removing a drive during this process causes data loss. One of the following conditions may exist: • The drive is part of an array being selected by ORCA. • The Options ROMPaq is upgrading the drive. One of the following conditions may exist: • The drive is not configured as part of an array. • If this drive is part of an array, a powered-on controller is not accessing the drive. • The drive is configured as an online spare. It is OK to replace the drive online if a predictive failure alert is received and the drive is attached to an array controller. The drive has failed and has been placed offline. It is OK to replace the drive online. The drive is online and configured as part of an array. It is OK to replace the drive online if a predictive failure alert is received, provided that the array is configured for fault tolerance and all other drives in the array are online. The drive is online and is being accessed. It is OK to replace the drive online if a predictive failure alert is received, provided that the array is configured for fault tolerance and all other drives in the array are online.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

24
HP ProLiant DL560 Server User Guide
Hot-Plug SCSI Hard Drive LED Combinations
Activity
LED
Online
LED
Fault
LED
Means
On
Off
Off
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is being accessed and is
not configured as part of an array.
On
Flashing
Off
Do not remove the drive. Removing a drive during this
process causes data loss.
The drive is rebuilding or undergoing
capacity expansion.
Flashing
Flashing
Flashing
Do not remove the drive. Removing a drive during this
process causes data loss.
One of the following conditions may
exist:
The drive is part of an array being selected by ORCA.
The Options ROMPaq
is upgrading the drive.
Off
Off
Off
One of the following conditions may exist:
The drive is not configured as part of an array.
If this drive is part of an array, a powered-on controller is not
accessing the drive.
The drive is configured as an online spare.
It is OK to replace the drive online if a predictive failure alert is
received and the drive is attached to an array controller.
Off
Off
On
The drive has failed and has been placed offline. It is OK to
replace the drive online.
Off
On
Off
The drive is online and configured as part of an array. It is OK to
replace the drive online if a predictive failure alert is received,
provided that the array is configured for fault tolerance and all
other drives in the array are online.
On or
flashing
On
Off
The drive is online and is being accessed. It is OK to replace the
drive online if a predictive failure alert is received, provided that
the array is configured for fault tolerance and all other drives in the
array are online.