HP DL560 HP ProLiant DL560 Server User Guide - Page 66

Battery-Backed Write Cache Enabler Option, To install the Battery-Backed Write Cache Enabler

Page 66 highlights

66 HP ProLiant DL560 Server User Guide Battery-Backed Write Cache Enabler Option The Battery-Backed Write Cache Enabler, also known as the battery module, provides transportable data protection, increases overall controller performance, and maintains any cached data for up to 72 hours. The NiMH batteries in the battery module are continuously recharged through a trickle-charging process whenever the system power is on. Under normal operating conditions, the battery module lasts for 3 years before replacement is necessary. For information on battery module LEDs, refer to "Battery-Backed Write Cache Enabler LEDs." CAUTION: To prevent damage to the equipment or server malfunction, do not add or remove the battery module while an array capacity expansion, RAID level migration, or stripe size migration is in progress. CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cable from the battery module. If the amber LED blinks after 15 seconds, do not remove the cable from the battery module. The battery module is backing up data, and data will be lost if the cable is detached. IMPORTANT: The battery module may have a low charge when installed. In this case, a POST error message is displayed when the server is powered up, indicating that the battery module is temporarily disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries and enables the battery module. This process may take up to 4 hours. During this time, the array controller will function properly but without the performance advantage of the battery module. NOTE: The data protection and the time limit also applies if a power outage occurs. When power is restored to the system, an initialization process writes the preserved data to the hard drives. To install the Battery-Backed Write Cache Enabler: 1. Power down the server ("Powering Down the Server" on page 29). 2. Extend the server from the rack, if applicable ("Extending the Server from the Rack" on page 30).

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136

66
HP ProLiant DL560 Server User Guide
Battery-Backed Write Cache Enabler Option
The Battery-Backed Write Cache Enabler, also known as the battery module,
provides transportable data protection, increases overall controller performance,
and maintains any cached data for up to 72 hours. The NiMH batteries in the
battery module are continuously recharged through a trickle-charging process
whenever the system power is on. Under normal operating conditions, the battery
module lasts for 3 years before replacement is necessary.
For information on battery module LEDs, refer to "Battery-Backed Write Cache
Enabler LEDs."
CAUTION:
To prevent damage to the equipment or server
malfunction, do not add or remove the battery module while an array
capacity expansion, RAID level migration, or stripe size migration is in
progress.
CAUTION:
After the server is powered down, wait 15 seconds
and then check the amber LED before unplugging the cable from the
battery module. If the amber LED blinks after 15 seconds, do not
remove the cable from the battery module. The battery module is
backing up data, and data will be lost if the cable is detached.
IMPORTANT:
The battery module may have a low charge when
installed. In this case, a POST error message is displayed when the
server is powered up, indicating that the battery module is temporarily
disabled. No action is necessary on your part. The internal circuitry
automatically recharges the batteries and enables the battery module.
This process may take up to 4 hours. During this time, the array
controller will function properly but without the performance advantage
of the battery module.
NOTE:
The data protection and the time limit also applies if a power
outage occurs. When power is restored to the system, an initialization
process writes the preserved data to the hard drives.
To install the Battery-Backed Write Cache Enabler:
1.
Power down the server ("Powering Down the Server" on page 29).
2.
Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page 30).