System LED and, Color, Internal Health, LED Color, Status, error threshold.
UPC - 808736876919
View all HP DL560 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Server Component Identification 21 System LED and Color Processor failure, socket X (Amber) Internal Health LED Color Red Amber Processor failure, two Red or more sockets (Amber) PPM failure, slot X Red (Amber) DIMM failure, slot X Red (Amber) Amber Overtemperature Red (Amber) Riser interlock (Amber) Peripheral board interlock (Amber) Fan (Amber) Red Red Amber Red Status • Processor in socket X has failed. • Processor in socket X failed over to the offline spare. • Processor X is not installed in the socket. • Processor X is unsupported. • ROM detects a failed processor during POST. Processor in socket X is in a pre-failure condition. Processor types are mismatched. • PPM in slot X has failed. • PPM is not installed in slot X, but the corresponding processor is installed. • DIMM in slot X has failed. • DIMM in slot X is an unsupported type, and no valid memory exists in another bank. • DIMM in slot X has reached single-bit correctable error threshold. • DIMM in slot X is in a pre-failure condition. • DIMM in slot X is an unsupported type, but valid memory exists in another bank. • Health Driver has detected a cautionary temperature level. • Server has detected a hardware critical temperature level. PCI riser cage is not seated. Peripheral board is not seated. Redundant fan has failed. The minimum fan requirements are not being met. One or more fans have failed or are missing.