HP R1500 HP 3 Phase UPS User Guide - Page 103

UPS output specifications, Environmental specifications

Page 103 highlights

UPS output specifications Nominal output voltage Output voltage variation (standard) Output voltage variation (reduced) Output receptacles on standalone UPSs-12kVA models Output receptacles on standalone UPSs-8kVA Short circuit capability (Battery Mode) Short circuit capability (Normal Mode) Nominal output frequency Output frequency variation Output overload Voltage waveform Full output 3 Phase UPS NA 120/208 Vac three-phase 108-132 Vac phase to neutral 3 Phase UPS INTL 230/400 Vac three-phase 187-255 Vac phase to neutral 187-229 Vac phase to phase 108-132 Vac phase to neutral 324-441 Vac phase to phase 207-253 Vac phase to neutral 187-229 Vac phase to phase Output module (2x L15-30R) 358-438 Vac phase to phase Output module (2x IEC 309-16 A, 5 wire) 1x L15-30R 1x IEC 309-16 A, 5 wire 84 A, 150%: load transfers to Auto-Bypass Mode after 300 ms Mode after 300 ms Normal Mode and Battery Mode: Normal Mode and Battery Mode: Sine wave;

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115

Specifications 103
UPS output specifications
3 Phase UPS NA
3 Phase UPS INTL
Nominal output voltage
120/208 Vac three-phase
230/400 Vac three-phase
Output voltage variation
(standard)
108-132 Vac phase to neutral
187-255 Vac phase to neutral
187-229 Vac phase to phase
324-441 Vac phase to phase
Output voltage variation
(reduced)
108-132 Vac phase to neutral
207-253 Vac phase to neutral
187-229 Vac phase to phase
358-438 Vac phase to phase
Output receptacles on
standalone UPSs—12kVA
models
Output module (2x L15-30R)
Output module (2x IEC 309-16 A, 5
wire)
Output receptacles on
standalone UPSs—8kVA
1x L15-30R
1x IEC 309-16 A, 5 wire
Short circuit capability
(Battery Mode)
84 A, <300 ms
44 A, <300 ms
Short circuit capability
(Normal Mode)
Limited by 50 A input breaker (30 A
source on 8kVA models)
Limited by 30 A input breaker (16 A
source on 8kVA models)
Nominal output frequency
50-60 Hz auto-detection (Normal
Mode)
50-60 Hz auto-detection (Normal
Mode)
50 or 60 Hz (Battery Mode)
50 or 60 Hz (Battery Mode)
Output frequency variation
Synchronized (Normal Mode)
Synchronized (Normal Mode)
±0.1 when not synchronized with
source (Battery Mode)
±0.1 when not synchronized with
source (Battery Mode)
Output overload
100-110%:
load transfers to
Auto-Bypass Mode after 10 minutes
100-110%:
load transfers to
Auto-Bypass Mode after 10 minutes
110-125%:
load transfers to
Auto-Bypass Mode after 1 minute
110-125%:
load transfers to
Auto-Bypass Mode after 1 minute
125-150%:
load transfers to
Auto-Bypass Mode after 5 seconds
125-150%:
load transfers to
Auto-Bypass Mode after 5 seconds
>150%:
load transfers to Auto-Bypass
Mode after 300 ms
>150%:
load transfers to Auto-Bypass
Mode after 300 ms
Voltage waveform
Normal Mode and Battery Mode:
Sine wave; <2% THD with linear load;
<5% with nonlinear load
Normal Mode and Battery Mode:
Sine wave; <2% THD with linear load;
<5% with nonlinear load
Full output
Three-phase
Three-phase
Environmental specifications
Feature
Specification
Operating
temperature
0°C to 40°C (32°F to 104°F)
Optimal battery performance:
5°C to 25°C (41°F to
77°F)
Storage temperature
0°C to 25°C (32°F to 77°F)
Transit temperature
-25°C to 55°C (-13°F to 131°F)