HP R1500 HP 3 Phase UPS User Guide - Page 94

Troubleshooting, LED and audible alarm troubleshooting

Page 94 highlights

Troubleshooting LED and audible alarm troubleshooting This UPS is designed for durable, automatic operation and also alerts you whenever potential operating problems might occur. Usually the alarms shown on the control panel do not mean that the output power is affected. Instead, they are preventive alarms intended to alert you of a possible condition. The following table describes typical alarms and conditions. If an alarm appears with a service code, contact HP technical support ("HP contact information" on page 107). To check the Event Log for a list of active alarms: 1. Press any button on the front panel display to activate the menu options. 2. Press the down arrow button until EVENT LOG displays. 3. Press the right arrow button to display the list of alarms and conditions. Alarm On Battery Power On Auto-Bypass LED LED LED LED Audible alarm Condition On On On On On Flashing On Flashing UPS is in Normal mode (on page 65). A new message is active. On-1 beep On Battery ("UPS is every 5 seconds on battery" on page 100) On-Continuous Battery Low for 10 seconds ("Battery low condition" on page 96) On-1 beep Battery Breaker (on every 3 seconds page 95) On-1 beep On Bypass ("UPS is every 3 seconds on bypass" on page 100) On-1 beep every 1 seconds Bypass Unavailable ("Bypass is unavailable" on page 96) On-1 beep every 3 seconds Battery Connection ("Battery connection condition" on page 96) Troubleshooting 94

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115

Troubleshooting 94
Troubleshooting
LED and audible alarm troubleshooting
This UPS is designed for durable, automatic operation and also alerts you whenever potential operating
problems might occur. Usually the alarms shown on the control panel do not mean that the output power is
affected. Instead, they are preventive alarms intended to alert you of a possible condition.
The following table describes typical alarms and conditions. If an alarm appears with a service code, contact
HP technical support ("
HP contact information
" on page
107
).
To check the Event Log for a list of active alarms:
1.
Press any button on the front panel display to activate the menu options.
2.
Press the down arrow button until
EVENT LOG
displays.
3.
Press the right arrow button to display the list of alarms and conditions.
Alarm
LED
On Battery
LED
Power On
LED
Auto-Bypass
LED
Audible alarm Condition
On
UPS is in Normal
mode (on page
65
).
Flashing
A new message is
active.
On
On—1 beep
every 5 seconds
On Battery ("
UPS is
on battery
" on
page
100
)
On
On—Continuous
for 10 seconds
Battery Low
("
Battery low
condition
" on page
96
)
On
On—1 beep
every 3 seconds
Battery Breaker (on
page
95
)
On
On—1 beep
every 3 seconds
On Bypass ("
UPS is
on bypass
" on
page
100
)
Flashing
On—1 beep
every 1 seconds
Bypass
Unavailable
("
Bypass is
unavailable
" on
page
96
)
On
On—1 beep
every 3 seconds
Battery Connection
("
Battery
connection
condition
" on page
96
)