OTHERS Specifications Camera Signal system: NTSC standard Image device: IT CCD Effective picture elements: 380,000 pixels, (H) 768 × (V) 494 Image size: 1/4" Sync system: Internal Line lock (Only possible in 60 Hz regions.) Scanning frequency: Horizontal: 15.734 kHz Vertical: 59.94 Hz Horizontal resolution: 470 TV lines Video S/N: 50 dB (typical) ...(AGC OFF) Minimum illumination: 4 lx (F1.0, AGC 20 dB, Y: 25%) White balance: ATW (auto tracking)/AWC (auto white control) Manual (2-axis system) Electronic shutter: 1/60 s (standard) 1/100 s (50 Hz flickerless) Electronic zoom: Possible (×2) Character display: Possible Backlight compensation: Available by adjustment of light metering area position. Color level adjustment: Possible Contour compensation: Horizontal, vertical Moving mechanism Panning: ±30° Panning speed: 2°/s, 4°/s, 6°/s, 12°/s, 20°/s, 40°/s, 60°/s, 80°/s (in MANUAL mode) 4°/s (AUTO PAN mode) 120°/s (Preset maximum) Tilting: 0° to 60° (from down to horizontal direction) Tilting speed: 2°/s, 4°/s, 6°/s, 12°/s, 20°/s, 40°/s, 60°/s, 80°/s (in MANUAL mode) 120°/s (Preset maximum) General Power requirement: AC 24V 50/60Hz, 9.0W Communications port: RS-422A/RS-485 or RS-232C (switchable) 9600 bit/s Ambient temperature: -10°C to 50°C (operating) 0°C to 40°C (recommended) Mass: 0.8 kg (including ceiling mount) Accessories: Instructions ×1 Warranty Card ×1 Service Information Card × 1 Ceiling Mount ×1 Terminal Board ×1 Lens Focal length: f = 2.2 mm Max. aperture ratio: F1.0 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35

33
3.
Setting of Alarm Condition Duration (DURATION)
Set how long the alarm condition should last from when the alarm signal is supplied.
(
Z
See page 24.)
Memo:
When a new alarm signal is input during the alarm condition, the alarm condition is prolonged.
4.
Setting the Alarm Position (POSITION)
Set the preset position to be invoked when the alarm condition is generated.
(
Z
See page 24.)
5.
Setting the Alarm Text Size (ALM. TEXT SIZE)
The “ALARM” text indication can be displayed on the screen to indicate the alarm con-
dition when this is generated. The size of the characters should be set. (
Z
See page
20.)
Memo:
Minimum 70 ms or more is required for the camera body to detect the switched condition of the
contact.
Example: In the case of MAKE
70 ms
SHORT
Alarm detection
Alarm detection not
guaranteed
OPEN
70 ms or
more