Motorola SB5100 Installation Manual - Page 76

Event Log Messages, Level, Cable Modem Actions, file. Log it. If Reg-Response returns OK - config file

Page 76 highlights

B-4 Event Log Messages Code I103.0 Event Log Messages Required TLVs out of order. Level Cable Modem Actions I104.0 I105.0 I105.1 I105.2 I106.0 I106.1 I107.0 I108.0 I109.0 I110.0 I111.0 I111.1 I112.0 I112.1 I113.0 I113.1 I114.0 I114.1 I114.2 I114.3 I114.4 I115.0 Required TLVs not present. Down Stream Frequency format invalid in length. Down Stream Frequency not in use. Down Stream Frequency invalid, not a multiple of 62500Hz. 4 (Error) 4 (Error) Up Stream Channel invalid, unassigned. Up Stream Channel Change followed with (RE-) Registration REQ. Up Stream Channel overloaded. Network Access configuration has invalid parameter (length). Class of Service configuration is invalid. Class of Service ID is not in TFTP config. Class of Service ID out of range. 4 (Error) 4 (Error) 7 (Info) 4 (Error) Class of Service ID invalid length Max Downstream Bit rate configuration has invalid length Max Downstream Bit Rate configuration is not in TFTP config. Max Upstream Bit rate configuration has invalid length Max Upstream Bit Rate configuration is not in TFTP config Up Stream Priority configuration invalid format. Up Stream Priority configuration setting out of range. 4 (Error) 4 (Error) 7 (Info) 4 (Error) 7 (Info) 4 (Error) 4 (Error) Upstream Priority configuration has invalid length Vendor Spec has invalid length/type of vendor ID Vendor Spec has invalid length 4 (Error) 4 (Error) 4 (Error) Min Upstream Channel Bit Rate configuration setting invalid length 4 (Error) Won't be saved to memory CM will continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Set to 0 value No action taken Continue reading next bytes of Config file. Log it. If Reg-Response returns OK, reboot to notify CMTS the range error Continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Continue reading next bytes of Config file. Set to 7 value as lowest priority Set to correct length and continue reading next bytes of Config file. Set to correct length and continue reading next bytes of Config file. Set to correct length and continue reading next bytes of Config file. Continue reading next bytes of Config file. Set to 0 value SURFboard Cable Modem Installation Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

B-4
Event Log Messages
SURFboard Cable Modem Installation Manual
Code
Event Log Messages
Level
Cable Modem Actions
I103.0
Required TLVs out of order.
I104.0
Required TLVs not present.
I105.0
Down Stream Frequency format invalid in
length.
4 (Error)
Won°t be saved to memory
I105.1
Down Stream Frequency not in use.
I105.2
Down Stream Frequency invalid, not a
multiple of 62500Hz.
4 (Error)
CM will continue reading next bytes of
Config file.
Set to 0 value
I106.0
Up Stream Channel invalid, unassigned.
4 (Error)
I106.1
Up Stream Channel Change followed with
(RE-) Registration REQ.
I107.0
Up Stream Channel overloaded.
I108.0
Network Access configuration has invalid
parameter (length).
4 (Error)
Continue reading next bytes of Config
file. Set to 0 value
I109.0
Class of Service configuration is invalid.
I110.0
Class of Service ID is not in TFTP config.
7 (Info)
No action taken
I111.0
Class of Service ID out of range.
4 (Error)
Continue reading next bytes of Config
file. Log it. If Reg-Response returns OK,
reboot to notify CMTS the range error
I111.1
Class of Service ID invalid length
4 (Error)
I112.0
Max Downstream Bit rate configuration
has invalid length
4 (Error)
Continue reading next bytes of Config
file. Set to 0 value
I112.1
Max Downstream Bit Rate configuration is
not in TFTP config.
7 (Info)
Continue reading next bytes of Config
file. Set to 0 value
I113.0
Max Upstream Bit rate configuration has
invalid length
4 (Error)
Continue reading next bytes of Config
file. Set to 0 value
I113.1
Max Upstream Bit Rate configuration is
not in TFTP config
7 (Info)
Continue reading next bytes of Config
file.
I114.0
Up Stream Priority configuration invalid
format.
4 (Error)
I114.1
Up Stream Priority configuration setting
out of range.
4 (Error)
Continue reading next bytes of Config
file.
Set to 7 value as lowest priority
I114.2
Upstream Priority configuration has invalid
length
4 (Error)
Set to correct length and continue
reading next bytes of Config file.
I114.3
Vendor Spec has invalid length/type of
vendor ID
4 (Error)
Set to correct length and continue
reading next bytes of Config file.
I114.4
Vendor Spec has invalid length
4 (Error)
Set to correct length and continue
reading next bytes of Config file.
I115.0
Min Upstream Channel Bit Rate
configuration setting invalid length
4 (Error)
Continue reading next bytes of Config
file. Set to 0 value