Motorola SB5100 Installation Manual - Page 76
Event Log Messages, Level, Cable Modem Actions, file. Log it. If Reg-Response returns OK - config file
UPC - 612572073193
View all Motorola SB5100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
B-4 Event Log Messages Code I103.0 Event Log Messages Required TLVs out of order. Level Cable Modem Actions I104.0 I105.0 I105.1 I105.2 I106.0 I106.1 I107.0 I108.0 I109.0 I110.0 I111.0 I111.1 I112.0 I112.1 I113.0 I113.1 I114.0 I114.1 I114.2 I114.3 I114.4 I115.0 Required TLVs not present. Down Stream Frequency format invalid in length. Down Stream Frequency not in use. Down Stream Frequency invalid, not a multiple of 62500Hz. 4 (Error) 4 (Error) Up Stream Channel invalid, unassigned. Up Stream Channel Change followed with (RE-) Registration REQ. Up Stream Channel overloaded. Network Access configuration has invalid parameter (length). Class of Service configuration is invalid. Class of Service ID is not in TFTP config. Class of Service ID out of range. 4 (Error) 4 (Error) 7 (Info) 4 (Error) Class of Service ID invalid length Max Downstream Bit rate configuration has invalid length Max Downstream Bit Rate configuration is not in TFTP config. Max Upstream Bit rate configuration has invalid length Max Upstream Bit Rate configuration is not in TFTP config Up Stream Priority configuration invalid format. Up Stream Priority configuration setting out of range. 4 (Error) 4 (Error) 7 (Info) 4 (Error) 7 (Info) 4 (Error) 4 (Error) Upstream Priority configuration has invalid length Vendor Spec has invalid length/type of vendor ID Vendor Spec has invalid length 4 (Error) 4 (Error) 4 (Error) Min Upstream Channel Bit Rate configuration setting invalid length 4 (Error) Won't be saved to memory CM will continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Set to 0 value No action taken Continue reading next bytes of Config file. Log it. If Reg-Response returns OK, reboot to notify CMTS the range error Continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Set to 0 value Continue reading next bytes of Config file. Continue reading next bytes of Config file. Set to 7 value as lowest priority Set to correct length and continue reading next bytes of Config file. Set to correct length and continue reading next bytes of Config file. Set to correct length and continue reading next bytes of Config file. Continue reading next bytes of Config file. Set to 0 value SURFboard Cable Modem Installation Manual