Panasonic WJRT416V WJRT416V User Guide - Page 44

Connection with PS·Data systems, PS.Data Setup of Communication Setup, on the Setup Menu

Page 44 highlights

Connection with PS·Data systems This is an example of connection when the unit is used together with the PS·Data devices. If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the system controller. Use the RS485 cable provided with the system controller. Important: • Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions of how to terminate. Termination of this unit can be set with the mode selection DIP switch on the rear panel. (See page 47.) • When connecting a PS·Data compatible device, it is necessary to set each item of "PS.Data Setup" of "Communication Setup" according to the system configuration. • The following are available PS·Data compatible devices. • System controller: WV-CU650 (Ver 2.10 or later) • Data multiplex unit: WJ-MP204 • Matrix switcher: WJ-SX650 (Ver. 3.00 or later) (Any other PS·Data compatible devices are not to be connected.) When connecting a single unit with a controller Controller Termination: ON Unit Address: 1 SYSTEM CONTROLLER 123 456 789 0 A B RS485 cable (provided with the controller) ON Mode selection DIP switches 12 AUX IN SERIAL RS485(CAMERA) AUDIO IN/ALARM OUT 5 3 1 POWER ON OFF AUDIO OUT MONITOR1 MONITOR2 DATA 12 MODE 10/100BASE-T COPY1 ALARM IN/CONTOROL 6 4 AUDIO IN 2 SIGNAL GND IN 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 OUT AC IN 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 VIDEO This unit "PS.Data Setup" of "Communication Setup" on the Setup Menu • Unit Address (System): 1 • Unit Address (Controller): 2 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

44
Connection with PS·Data systems
This is an example of connection when the unit is used together with the PS·Data devices.
If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the sys-
tem controller.
Use the RS485 cable provided with the system controller.
Important:
Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions
of how to terminate. Termination of this unit can be set with the mode selection DIP switch on the rear panel. (See page
47.)
• When connecting a PS·Data compatible device, it is necessary to set each item of "PS.Data Setup" of "Communication
Setup" according to the system configuration.
The following are available PS·Data compatible devices.
System controller: WV-CU650 (Ver 2.10 or later)
Data multiplex unit: WJ-MP204
Matrix switcher: WJ-SX650 (Ver. 3.00 or later)
(Any other PS·Data compatible devices are not to be connected.)
When connecting a single unit with a controller
AUX IN
AUDIO OUT
IN
OUT
16
15
14
13
12
11
10
9
8
7
6
5
4
3
5
3
1
6
4
2
1
2
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
MONITOR1
MONITOR2
RS485(CAMERA)
MODE
12
DATA
10/100BASE-T
COPY1
ALARM IN/CONTOROL
AUDIO IN
SIGNAL GND
POWER
ON
OFF
AC IN
AUDIO IN/ALARM OUT
VIDEO
SERIAL
This unit
1
ON
2
Mode selection
DIP switches
A
B
1
3
2
4
6
5
7
9
8
0
Controller
Termination: ON
Unit Address: 1
RS485 cable
(provided with the controller)
"PS.Data Setup" of "Communication Setup"
on the Setup Menu
Unit Address (System):
1
Unit Address (Controller):
2