Panasonic WJRT416V WJRT416V User Guide - Page 64

Con the RS485 settings [RS485 Setup], Setup], Baud Rate, Default, Data Bit, Parity, Stop Bit

Page 64 highlights

Advanced Setup The following window will be displayed when the [SET] button is pressed after moving the cursor onto "Set→". Network Setup (Advanced) DNS Off IP Address (Primary IP Address (Secondary Server Port 02000 OK Cancel DNS Select "Manual" or "Auto" to enable IP address searching by the host name using the DNS. Select "Off" when not using the DNS. Selecting "Auto" is available only when "On" is selected for "DHCP" (using the DHCP server). When "Manual" is selected for the DNS, enter the DNS server addresses in "IP Address (Primary)" and "IP Address (Secondary)". Enter 4 units from the decimal numbers (0-255) according to the network configuration. Default: Off Server Port Set the server port number of the recorder (required to use the monitoring software). 1 - 65535 Default: 2000 w Configure the RS485 settings [RS485 Setup] Configure the RS485 settings. RS485 Setup Baud Rate 19200 Data Bit 8 Parity None Stop Bit 1 OK Cancel Baud Rate Select a line speed for data communication with the connected device from the following. 2 400/4 800/9 600/19 200/38 400 (bps) Default: 19 200 (bps) Data Bit The data bit will be displayed. It is impossible to change the value. Parity A method of checking for errors in communication functioning will be displayed. It is impossible to change the value. Stop Bit The stop bit type will be displayed. It is impossible to change the value. e Configure the PS·Data settings [PS.Data Setup] Configure the PS·Data settings. PS.Data Setup Unit Address(System) 001 Unit Address(Controller) 002 Baud Rate 9600 Data Bit 8 Parity None Stop Bit 1 Retry Timing Off Alarm Data 1s Camera Number Setup Set OK Cancel Unit Address (System) A unit address (Sys) is a unique number assigning to PS·Data devices. The addresses must be unique to identify system devices when connecting multiple devices compatible with PS·Data. Numbers, "001"-"099", are to be assigned as the unit addresses to the system devices. Default: 001 Unit Address (Controller) A unit address (Ctrl) is a unit address assigning to control PS·Data devices. Numbers, "002"-"099", are to be assigned as the unit addresses to the system controller. Default: 002 64

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

64
Baud Rate
Select a line speed for data communication with the con-
nected device from the following.
2 400/4 800/9 600/19 200/38 400 (bps)
Default:
19 200 (bps)
Data Bit
The data bit will be displayed. It is impossible to change
the value.
Parity
A method of checking for errors in communication function-
ing will be displayed. It is impossible to change the value.
Stop Bit
The stop bit type will be displayed. It is impossible to
change the value.
Unit Address (System)
A unit address (Sys) is a unique number assigning to
PS·Data devices. The addresses must be unique to
identify system devices when connecting multiple
devices compatible with PS·Data.
Numbers, "001"-"099", are to be assigned as the unit
addresses to the system devices.
Default:
001
Unit Address (Controller)
A unit address (Ctrl) is a unit address assigning to con-
trol PS·Data devices. Numbers, "002"-"099", are to be
assigned as the unit addresses to the system controller.
Default:
002
Advanced Setup
The following window will be displayed when the [SET] but-
ton is pressed after moving the cursor onto "Set
".
DNS
Select "Manual" or "Auto" to enable IP address searching by
the host name using the DNS.
Select "Off" when not using the DNS.
Selecting "Auto" is available only when "On" is selected for
"DHCP" (using the DHCP server).
When "Manual" is selected for the DNS, enter the DNS serv-
er addresses in "IP Address (Primary)" and "IP Address
(Secondary)".
Enter 4 units from the decimal numbers (0-255) according
to the network configuration.
Default:
Off
Server Port
Set the server port number of the recorder (required to use
the monitoring software).
1 - 65535
Default:
2000
w
Configure the RS485 settings [RS485 Setup]
Configure the RS485 settings.
e
Configure the PS·Data settings [PS.Data
Setup]
Configure the PS·Data settings.
OK
Network Setup (Advanced)
Cancel
Off
DNS
---.---.---.---
IP Address (Primary)
---.---.---.---
IP Address (Secondary)
02000
Server Port
RS485 Setup
OK
19200
Baud Rate
Cancel
8
Data Bit
None
Parity
1
Stop Bit
001
Unit Address(System)
002
Unit Address(Controller)
9600
Baud Rate
None
Parity
1
Stop Bit
Off
Retry Timing
1s
Alarm Data
Set
Camera Number Setup
8
Data Bit
PS.Data Setup
OK
Cancel