Sharp GX30 Service Manual - Page 20

Note], Error screen

Page 20 highlights

GX30 CONFIDENTIAL You can shorten time for the MOT file rewrite operation by selecting a smaller value for Wait Time. Example: Time to rewrite two MOT files at a time. At the default setting (8 seconds), rewrite time is approximately one hour. If the value is set to 1, the rewrite time will be reduced to approximately 30 minutes. If an error occurs at 1, increase the value. The error screen will appear on handsets No. 2 to No.10. If this screen appears, increase Wait Time and retry. Error screen Flash Loader 5.02 CORRESPONDENCE_ERROR Figure 29 When the File System Initialize check box is checked, a confirmation message appears. Click the [OK] button. Figure 30 [Note] When you check File System Initialize check box and click the "OK" button, handset status returns to the default. In this case, user data is initialized after the MOT file rewrite operation. Uncheck the check box to avoid this. 2 - 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

GX30
2 – 12
CONFIDENTIAL
You can shorten time for the MOT file rewrite operation by selecting a smaller value for Wait Time.
Example: Time to rewrite two MOT files at a time.
At the default setting (8 seconds), rewrite time is approximately one hour.
If the value is set to 1, the rewrite time will be reduced to approximately 30 minutes.
If an error occurs at 1, increase the value.
The error screen will appear on handsets No. 2 to No.10.
If this screen appears, increase Wait Time and retry.
Figure 29
When the File System Initialize check box is checked, a confirmation message appears.
Figure 30
[Note]
When you check File System Initialize check box and click the “OK” button, handset status returns to the default.
In this case, user data is initialized after the MOT file rewrite operation. Uncheck the check box to avoid this.
Flash Loader 5.02
CORRESPONDENCE_ERROR
Error screen
Click the [OK] button.