Sharp GX30 Service Manual - Page 48
Black defect correction, Requirements, Procedure,
View all Sharp GX30 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
GX30 CONFIDENTIAL When an error occurs, the corresponding message appears. Solve the problem according to "Solution". • Error 1 Error message: "There are too many white cracks." Cause: The light is not sufficiently blocked. Solution: Block the light completely and perform white defect correction again. • Error 2 Error message: "There are many white cracks." Cause: The light is not sufficiently blocked. Solution: Block the light completely and perform white defect correction again. • Error 3 Error message: "There are too many white cracks cannot be rectified." Cause: There is a hardware error. Solution: Replace the camera unit. 4.8.17 Black defect correction *Black defect correction: Defective pixels in a camera light sensor appear as black points in the display even when a captured image is completely white (display is all white). Perform black defect correction to eliminate errors in these pixels. 1) Requirements • Desk top type of fluorescent lamp • Black defect correction sheet Figure 79 • Illuminance meter 2) Procedure 1. Cover the camera section with the black defect correction sheet as shown in Figure 80. Attach the sheet to the handset firmly with clear scotch tape. Figure 80 2 - 40