Error Messages, Error, Possible Causes
View all Texas Instruments BA-20 Profit Manager manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Error Messages Note: To clear an error message, press P. Error Error 1 Overflow Possible Causes • A result is outside the calculator range (± 9.9999999999999E99). • Tried to divide by zero (can occur internally). • Tried to compute 1/x when x is zero. • Statistics worksheet: a calculation included X or Y values that are all the same. Error 2 Invalid argument • Tried to compute x! when x is not an integer 0-69. • Tried to compute LN of x when x is not > 0. • Tried to compute yx when y < 0 and x is not an integer or the inverse of an integer. • Tried to compute x when x < 0. • Amortization worksheet: tried to compute BAL, PRN, and INT when P2 < P1. • Depreciation worksheet: a calculation included SAL > CST. Error 3 Too many pending operations • More than 15 active levels of parentheses were tried in a calculation. • A calculation tried to use more than 8 pending operations. Error 4 • Amortization worksheet: the value entered for P1 Out of range or P2 is outside the range 1-9,999. • TVM worksheet: the P/Y or C/Y value 0. • Cash Flow worksheet: the Fnn value is outside the range 0.5-9,999. • Bond worksheet: the RV, CPN, or PRI value _0. • Date worksheet: the computed date is outside the range January 1, 1950 through December 31, 2049. • Depreciation worksheet: the value entered for: declining balance percent 0; LIF 0; YR _ 0; CST < 0; SAL < 0; or M01 1 M01 13. • Interest Conversion worksheet: the C/Y value 0. • The DEC value is outside the range 0-9. 94 Appendix - Reference Information