Toshiba Satellite A300 Maintenance Manual - Page 181
Installing the LCD unit/FL Inverter, screws, LCD unit, LCD harness, conductive tape, display mask
View all Toshiba Satellite A300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 181 highlights
Replacement Procedures Installing the LCD unit/FL Inverter The following describes the procedure for installing the LCD unit and FL inverter (See Figure 4-31 to 4-34). 1. Install the LCD supports (LCD unit side) to the LCD and secure them with the following screws. • M2.0×2.0 BINK screw x2 2. Stand the LCD unit on the display cover and connect the LCD harness to the connector on the back of LCD. 3. Stick the conductive tape on the connector of LCD harness. 4. Secure the LCD unit with the following screws. • M2.5×4.0 BINK screw x4 5. Connect LCD harnesses to the connector CN1 of the FL inverter. CAUTION: Be careful not to connect the LCD harnesses to the wrong connectors of FL inverter. 6. Connect HV harnesses to the connector CN2 of the FL inverter. 7. Install the display mask while fitting the latches. 8. Secure the display mask with following screws M2.5×5.0 BIND screw x6 9. Cover screws with Screw rubber cover x6 NOTE: When installing the display mask, make sure there is no gap between the display mask and the display cover. Satellite A300 Maintenance Manual(960-Q08) 50