2009 Kawasaki JET SKI Ultra 260X Owners Manual - Page 143
2009 Kawasaki JET SKI Ultra 260X Manual
Page 143 highlights
MAINTENANCE AND ADJUSTMENTS 141 the cap and connect a garden hose with • Remove a screw-in fitting on its end. Start the engine and allow it to idle before turning • on the water. the engine idle for several minutes with the • Let water running. off the water. Leave the engine idling. • Turn the engine few times to clear the water out of • Rev the exhaust system. CAUTION The engine must be running before the water is turned on, or water may flow back through the exhaust pipe into the engine, resulting in the possibility of severe internal damage. turn on the water and adjust the flow • Immediately so that a little trickle of water comes out of the bypass outlet in the right side of the hull. CAUTION Do not run the engine without cooling water flow for more than 15 seconds. Overheating will cause severe engine and exhaust system damage. off the engine, remove the garden hose, • Switch reinstall the cap securely. j A. Bypass Outlet