Adaptec 3210S User Guide - Page 145
T, SMART, spare, spare pool, stripe set RAID 0, stripe set of mirror sets RAID 0/1, stripe size
UPC - 760884138250
View all Adaptec 3210S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
Adaptec Storage Manager Pro User's Guide SMART Stands for Self-Monitoring Analysis and Reporting Technology. This technology is designed to determine the reliability status of a disk. If the SMART system determines that a disk failure is imminent, the user is notified and advised of the appropriate action to take. spare Disk drive that you designate as a replacement disk as part of the spare pool. If a drive in a redundant array fails, the controller looks for a spare drive on which to rebuild the data of the failed drive. spare pool One or more disk drives that you designate as replacements for any arrays on a controller. stripe set (RAID 0) An array type that is made up of two or more drives. The stripe set distributes, or stripes, data evenly across its respective drives in equal-sized sections called chunks. See also chunk; partition. stripe set of mirror sets (RAID 0/1) An array type that is made up of two or more equal-sized mirror sets. The data in a stripe set of mirror sets is redundant. See also mirror set (RAID 1); multilevel array. stripe set of RAID 5 sets (RAID 0/5) An array type that is made up of two or more equal-sized RAID 5 sets. The data in a stripe set of RAID 5 sets is redundant. See also RAID 5 set; multilevel array. stripe size Amount of data written to one partition before the controller moves to the next partition in a stripe set. T target ID See SCSI ID. Glossary-6