Alpine HCE-C305R Owners Manual - Page 27

Calibration

Page 27 highlights

Calibration Introduction What is Calibration? In order to effectively identify approaching objects, it is necessary to configure the guidance and install data. This data is entered during the Calibration mode and ensures the most consistent detection results. Also, the warning message language and the em/ inch selection can be set in the Calibration mode. • Recalibration is required whenever the camera position is changed or the camera is installed in a different vehicle. • If this camera system is used without being calibrated, or if the calibration sheet is not installed correctly, object detection performance will be degraded. Calibration must be performed. • If the vehicle height changes after calibration, the system must be re-calibrated. • Be sure the shift gear lever is in the P position and apply the hand brake before starting work. • Do not operate the gear lever during calibration. • Always work in a flat location. • When starting the engine, provide adequate ventilation around the car. • Make sure that all connections are securely made. • Do not work in a poorly lit place or in direct sunlight. Setting Flowchart Use the switch to perform calibration. After connecting the camera system with the navigation/monitor, prepare the car body. Set the SETUP switch of the control unit to "OFF:' Setting ACC to "ON" activates the system in the normal use mode. Switching between ~~calibration Mode" and 11Normal Use Mode" HCE-C305R has two modes: "Normal Use Mode" and "Calibration Mode:' You can use the SETUP switch on the control unit to switch the mode. If ACC is set to ON with the SETUP switch "ON': the system starts in the calibration mode, and if ACC is set to ON with the SETUP switch "OFF", the system starts in the normal use mode. The factory setting is "OFF". Preparation Accessory parts Calibration sheet CD Calibration sheet @ External box Interior box Affix the calibration sheet. Set the SETUP switch of the control unit to Necessary tools Tape measure Adhesive tape (for positioning mark) Set ACC to "ON'~ Perform calibration of the camera. Set ACC to "OFF'~ Pen (for positioning mark) 26-EN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

26-EN
Calibration
Introduction
What
is
Calibration?
In order to effectively identify approaching
objects, it
is
necessary to configure the guidance
and install data. This data
is
entered during the
Calibration mode and ensures the most consistent
detection results.
Also, the warning message language and the em/
inch selection can be set in the Calibration mode.
Recalibration
is
required whenever the camera
position
is
changed or the camera
is
installed in a
different vehicle.
If
this camera system
is
used
without
being
calibrated, or
if
the calibration sheet
is
not
installed
correctly, object detection performance will be
degraded. Calibration
must
be performed.
If
the vehicle height changes after calibration, the
system
must
be re-calibrated.
Be sure the shift gear lever
is
in the P position
and
apply the
hand
brake before starting work.
Do
not
operate the gear lever during calibration.
Always work in a
flat
location.
When
starting the engine, provide adequate
ventilation around the
car.
Make sure that all connections are securely made.
Do
not
work in a poorly lit place or in direct sunlight.
Setting Flowchart
Use the switch to perform calibration.
After connecting
the
camera system with
the
navigation/monitor, prepare
the
car body.
Affix
the
calibration sheet.
Set
the
SETUP switch
of
the
control
unit
to
Set
ACC
to
"ON'~
Perform calibration
of
the
camera.
Set
ACC
to
"OFF'~
Set
the
SETUP switch
of
the
control
unit
to
"OFF:'
Setting
ACC
to
"ON" activates
the
system in
the
normal use mode.
Switching between
~~calibration
Mode"
and
11
Normal Use Mode"
HCE-C305R has two modes: "Normal Use Mode"
and "Calibration
Mode:'
You
can use the SETUP
switch
on
the control unit to switch the mode. If
ACC
is
set to
ON
with the SETUP switch "ON':
the system starts in the calibration mode, and
if
ACC
is
set to
ON
with the SETUP switch
"OFF",
the system starts in the normal use mode. The
factory setting
is
"OFF".
Preparation
Accessory parts
Calibration sheet
CD
External box
Necessary tools
Tape measure
Pen (for positioning
mark)
Calibration sheet
@
Interior box
Adhesive tape (for
positioning mark)