Campbell Scientific IRGASON IRGASON Integrated CO2/H2O Open-Path Gas Analyzer - Page 31

Device Configuration Utility, Config, Apply, Send OS

Page 31 highlights

IRGASON® Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 7-2. Setup window in ECMon 7.15 Device Configuration Utility DevConfig software (Device Configuration Utility) may also be used to change settings, although ECMon is generally preferred because of its more user-friendly interface. DevConfig may be downloaded from the IRGASON, EC150 & EC155 Support CD (pn 27007), or may be downloaded free of charge from the Campbell Scientific website www.campbellsci.com). DevConfig requires a USB driver to communicate with the EC100, similar to ECMon. See Section 7.14, ECMon, for notes on installing a USB driver. After launching DevConfig, select "EC100" from the list of device types. The EC100 electronics should be connected to the PC with the EC100 USB cable (pn 26563) and the appropriate USB port selected before connecting. Once connected, the settings tab displays all the current settings. The Apply button must be clicked to save any changes. DevConfig is also used to send an updated operating system to the EC100 electronics. The Send OS tab gives directions on this procedure. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

IRGASON
®
Integrated CO
2
/H
2
O Open-Path Gas Analyzer and 3D Sonic Anemometer
FIGURE 7-2.
Setup window in ECMon
7.15 Device Configuration Utility
DevConfig software (
Dev
ice
Config
uration Utility) may also be used to
change settings, although ECMon is generally preferred because of its more
user-friendly interface.
DevConfig may be downloaded from the
IRGASON,
EC150 & EC155 Support CD
(pn 27007), or may be downloaded free of
charge from the Campbell Scientific website
www.campbellsci.com
).
DevConfig requires a USB driver to communicate with the EC100, similar to
ECMon.
See Section 7.14,
ECMon
, for notes on installing a USB driver.
After launching DevConfig, select “EC100” from the list of device types.
The
EC100 electronics should be connected to the PC with the EC100 USB cable
(pn 26563) and the appropriate USB port selected before connecting.
Once
connected, the settings tab displays all the current settings.
The
Apply
button
must be clicked to save any changes.
DevConfig is also used to send an updated operating system to the EC100
electronics.
The
Send OS
tab gives directions on this procedure.