Test Fixture Installed ZZ-301-Keyboard Error Keyboard failure. 1. A key is stuck. (ZZ represents the Try to free it. Keyboard Scan Code.) 2. Replace the keyboard. 303-Keyboard Controller System board, Check with your Error keyboard, or mouse Authorized COMPAQ controller failure. Reseller. 304-Keyboard or System Keyboard, keyboard 1. Make sure the Unit Error cable, or system board keyboard is failure. attached. 2. Run Diagnostics to determine which is in error. 3. Replace the part indicated. 40X-Parallel Port X Both external and Run the EISA Address Assignment internal ports are Configuration Utility. Conflict assigned to parallel port X Error Code Probable Source Action of Problem 402-Monochrome Adapter Monochrome display Replace the monochrome Failure controller. display controller. 501-Display Adapter Video display Replace the video board. Failure controller. 601-Diskette Controller Diskette controller 1. Make sure the Error circuitry failure. diskette drive cables are attached. 2. Replace the diskette drive and/or cable. 3. Replace the system board. 602-Diskette Boot Diskette in drive A Replace the diskette. not bootable. 605-Diskette Drive Type Mismatch in drive Run the EISA Error type. Configuration Utility to set diskette type correctly. 607-No Response Received Configuration error. Run the EISA at Primary Address From Configuration Utility. External Floppy Controller. Internal Floppy Controller Has Enabled. 611-Primary Floppy Port Configuration error. Run the EISA Address Assignment Configuration Utility Conflict and correct.
![](/manual_guide/products/compaq-prosignia-500-compaq-prosignia-family-pc-servers-maintenance-service-guide-4ffc417/24.png)