Compaq ProSignia 500 Compaq ProSignia Family of PC Servers Maintenance and Ser - Page 27

Drive Y Select F1 to, Operating in Interim

Page 27 highlights

drive(s). system will continue to operate in the Interim Data Recovery mode. 1787-Slot # Drive Array Hard drive X failed 1. Replace drive X as Operating in Interim or cable is loose or soon as possible. Recovery Mode. defective. Following 2. Check loose cables. Physical drive a system restart, this 3. Replace defective replacement needed: message reminds you cables. Drive X that drive X is defective and fault tolerance is being used. Error Code Probable Source Action of Problem 1788-Slot # Drive Drives are not Reinstall the drives Array Reports Incorrect installed in their correctly as indicated. Drive Replacement original positions, Press F1 to restart Drive(s) should have so the drives have the computer with the been replaced: Drive X been disabled. See drive array disabled. Drive(s) were note below. -Or- incorrectly replaced: Press F2 to use the Drive Y Select "F1" to drives as configured continue - drive array and lose all the will remain disabled. data on them. Select "F2" to reset configuration - all data will be lost. NOTE: The 1788 error message might also be displayed inadvertently due to a bad power cable connection to the drive or by noise on the data cable. If this message was due to a bad power cable connection, but not due to an incorrect drive replacement, repair the connection and press F2. Or; If this message was not due to a bad power cable connection, and no drive replacement took place, this could indicate noise on the data cable. Check cable for proper routing. 1789-Slot # Drive Array Cable or hard drive 1. Check the cable Physical Drive(s) Not failure. connections. Responding. 2. If cables are Check cables or replace connected, replace physical drive X. the drive. Select "F1" to continue 3. If you do not - drive array will want to replace the remain disabled. drives now, press Select "F2" to fail F2. drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 Error Hard drive error or Run the EISA wrong drive type. Configuration Utility and Diagnostics and correct. 1791-Disk 1 Error Hard drive error or Run the EISA

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

drive(s).
system will continue to
operate in the Interim
Data Recovery mode.
---------------------------------------------------------------------------
1787-Slot # Drive Array
Hard drive X failed
1. Replace drive X as
Operating in Interim
or cable is loose or
soon as possible.
Recovery Mode.
defective. Following
2. Check loose cables.
Physical drive
a system restart, this 3. Replace defective
replacement needed:
message reminds you
cables.
Drive X
that drive X is
defective and fault
tolerance is being
used.
---------------------------------------------------------------------------
Error Code
Probable Source
Action
of Problem
---------------------------------------------------------------------------
1788-Slot # Drive
Drives are not
Reinstall the drives
Array Reports Incorrect
installed in their
correctly as indicated.
Drive Replacement
original positions,
Press F1 to restart
Drive(s) should have
so the drives have
the computer with the
been replaced: Drive X
been disabled. See
drive array disabled.
Drive(s) were
note below.
-Or-
incorrectly replaced:
Press F2 to use the
Drive Y Select "F1" to
drives as configured
continue - drive array
and lose all the
will remain disabled.
data on them.
Select "F2" to reset
configuration - all
data will be lost.
NOTE: The 1788 error message might also be displayed inadvertently due to a
bad power cable connection to the drive or by noise on the data
cable. If this message was due to a bad power cable connection, but
not due to an incorrect drive replacement, repair the connection and
press F2. Or; If this message was not due to a bad power cable
connection, and no drive replacement took place, this could indicate
noise on the data cable. Check cable for proper routing.
---------------------------------------------------------------------------
1789-Slot # Drive Array
Cable or hard drive
1. Check the cable
Physical Drive(s) Not
failure.
connections.
Responding.
2. If cables are
Check cables or replace
connected, replace
physical drive X.
the drive.
Select "F1" to continue
3. If you do not
- drive array will
want to replace the
remain disabled.
drives now, press
Select "F2" to fail
F2.
drive(s) that are not
responding - Interim
Recovery Mode will be
enabled if configured
for fault tolerance.
---------------------------------------------------------------------------
1790-Disk 0 Error
Hard drive error or
Run the EISA
wrong drive type.
Configuration Utility
and Diagnostics and
correct.
---------------------------------------------------------------------------
1791-Disk 1 Error
Hard drive error or
Run the EISA