Compaq ProSignia 500 Compaq ProSignia Family of PC Servers Maintenance and Ser - Page 25

Not Been Detected By, Secondary Disk Port

Page 25 highlights

612-Secondary Floppy Configuration error. Run the EISA Port Address Assignment Configuration Utility Conflict and correct. 702-A coprocessor has Installed coprocessor Run the EISA been detected that was not configured. Configuration Utility not reported by CMOS. and correct. 703-CMOS Reports A Coprocessor or 1. Run the EISA Coprocessor That Has configuration error. Configuration Not Been Detected By Utility and correct. POST 2. Replace the coprocessor. 1151-COM Port 1 Both external and Run the EISA internal serial ports Configuration Utility are assigned to COM1. and correct. 1152-COM Port 2 Both external and Run the EISA internal serial ports Configuration Utility are assigned to COM2. and correct. Error Code Probable Source Action of Problem 1153-COM Port 3 Both external and Run the EISA internal serial ports Configuration Utility are assigned to COM3. and correct. 1154-COM Port 4 Both external and Run the EISA internal serial ports Configuration Utility are assigned to COM4. and correct. 1701-SCSI Controller A test on the Run Diagnostics. Failure Controller failed. Replace failed assembly as indicated or, contact your service provider. 1771-Primary Disk Port Internal and external Run the EISA Address Assignment hard drive controllers Configuration Utility Conflict are both assigned to and correct. the primary address. 1772-Secondary Disk Port Address Assignment Run the EISA Conflict. Internal Configuration Utility and external hard and correct. drive controllers are both assigned to the secondary address. 1777-Slot # Drive Array Configuration error. Run the EISA Controller has been Configuration Utility upgraded. Run System and correct. Configuration Utility 1778-Slot # Drive Array This message appears No action necessary. resuming Automatic Data whenever a controller Recovery process reset or power cycle occurs while Automatic

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

---------------------------------------------------------------------------
612-Secondary Floppy
Configuration error.
Run the EISA
Port Address Assignment
Configuration Utility
Conflict
and correct.
---------------------------------------------------------------------------
702-A coprocessor has
Installed coprocessor
Run the EISA
been detected that was
not configured.
Configuration Utility
not reported by CMOS.
and correct.
---------------------------------------------------------------------------
703-CMOS Reports A
Coprocessor or
1. Run the EISA
Coprocessor That Has
configuration error.
Configuration
Not Been Detected By
Utility and correct.
POST
2. Replace the
coprocessor.
---------------------------------------------------------------------------
1151-COM Port 1
Both external and
Run the EISA
internal serial ports
Configuration Utility
are assigned to COM1.
and correct.
---------------------------------------------------------------------------
1152-COM Port 2
Both external and
Run the EISA
internal serial ports
Configuration Utility
are assigned to COM2.
and correct.
---------------------------------------------------------------------------
Error Code
Probable Source
Action
of Problem
---------------------------------------------------------------------------
1153-COM Port 3
Both external and
Run the EISA
internal serial ports
Configuration Utility
are assigned to COM3.
and correct.
---------------------------------------------------------------------------
1154-COM Port 4
Both external and
Run the EISA
internal serial ports
Configuration Utility
are assigned to COM4.
and correct.
---------------------------------------------------------------------------
1701-SCSI Controller
A test on the
Run Diagnostics.
Failure
Controller failed.
Replace failed assembly
as indicated or, contact
your service provider.
---------------------------------------------------------------------------
1771-Primary Disk Port
Internal and external
Run the EISA
Address Assignment
hard drive controllers Configuration Utility
Conflict
are both assigned to
and correct.
the primary address.
---------------------------------------------------------------------------
1772-Secondary Disk Port
Address Assignment
Run the EISA
Conflict. Internal
Configuration Utility
and external hard
and correct.
drive controllers are
both assigned to the
secondary address.
---------------------------------------------------------------------------
1777-Slot # Drive Array
Configuration error.
Run the EISA
Controller has been
Configuration Utility
upgraded. Run System
and correct.
Configuration Utility
---------------------------------------------------------------------------
1778-Slot # Drive Array
This message appears
No action necessary.
resuming Automatic Data
whenever a controller
Recovery process
reset or power cycle
occurs while Automatic