The Intelligent Array Expansion System firmware is less than 1.14.

Page 45 highlights

To recognize the array accelerator board, run the EISA Configuration Utility. Controller communication failure occurred DAAD was unable to successfully issue commands to the controller in this slot. Check the indicators on the controller. Refer to Chapter 4 of this guide for a complete description of the indicator definitions. Controller detected. CMOS not present The EISA nonvolatile RAM is not configured. Run the EISA Configuration Utility to configure the nonvolatile RAM. Controller firmware needs upgrading The controller firmware is below the latest recommended version. Call your Authorized COMPAQ Reseller to obtain the latest upgraded firmware. Controller firmware needs upgrading (DAAD Error 102) You have the correct controller, however, the IDA firmware should be greater than 1.26. Call your Authorized COMPAQ Reseller to obtain the latest firmware. Controller is not configured The controller is not configured. If the controller was previously configured and you change drive locations, there may be a problem with the placement of the drives. DAAD examines each physical drive and looks for drives that have been moved to a different drive bay. Look for the messages that indicate which drives have been moved. If none appear and drive swapping did not occur, run the EISA Configuration Utility to configure the controller and nonvolatile RAM. Do not run the EISA Configuration Utility if you believe drive swapping has occurred. Controller needs replacing (DAAD Error 102) The IDA firmware is less than version 0.96. Replace the controller as soon as possible. Controller needs replacing (DAAD Error 104) The Intelligent Array Expansion System firmware is less than 1.14.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

To recognize the array accelerator board, run the EISA Configuration
Utility.
---------------------------------------------------------------------------
Controller communication failure occurred
DAAD was unable to successfully issue commands to the controller in this
slot.
Check the indicators on the controller. Refer to Chapter 4 of this guide
for a complete description of the indicator definitions.
---------------------------------------------------------------------------
Controller detected. CMOS not present
The EISA nonvolatile RAM is not configured.
Run the EISA Configuration Utility to configure the nonvolatile RAM.
---------------------------------------------------------------------------
Controller firmware needs upgrading
The controller firmware is below the latest recommended version.
Call your Authorized COMPAQ Reseller to obtain the latest upgraded
firmware.
---------------------------------------------------------------------------
Controller firmware needs upgrading
(DAAD Error 102)
You have the correct controller, however, the IDA firmware should be
greater than 1.26.
Call your Authorized COMPAQ Reseller to obtain the latest firmware.
---------------------------------------------------------------------------
Controller is not configured
The controller is not configured. If the controller was previously
configured and you change drive locations, there may be a problem with the
placement of the drives. DAAD examines each physical drive and looks for
drives that have been moved to a different drive bay.
Look for the messages that indicate which drives have been moved. If none
appear and drive swapping did not occur, run the EISA Configuration Utility
to configure the controller and nonvolatile RAM. Do not run the EISA
Configuration Utility if you believe drive swapping has occurred.
---------------------------------------------------------------------------
Controller needs replacing (DAAD Error 102)
The IDA firmware is less than version 0.96.
Replace the controller as soon as possible.
---------------------------------------------------------------------------
Controller needs replacing (DAAD Error 104)
The Intelligent Array Expansion System firmware is less than 1.14.