Memory Modules B, C, D, E, Run System Configuration A configuration error - bios

Page 29 highlights

reconfigure the COMPAQ IDA-2 without the Array Accelerator. Error Code Probable Source Action of Problem 1797-Slot # Drive Array Hard parity error Array Accelerator is - Array Accelerator Read while reading data disabled. Error Occurred. Data from posted writes in Array Accelerator memory. has been lost. Array Accelerator is disabled. 1798-Slot # Drive Array Hard parity error Array Accelerator - Array Accelerator while writing data to is disabled. Write Error Occurred. posted writes memory. Array Accelerator is disabled. 1799-Slot # Drive Array Volume failed due to Press F1 to continue - Drive(s) Disabled due loss of data in with logical drives to Array Accelerator posted-writes memory. disabled or F2 to Data Loss. Select "F1" accept data loss and to continue with logical reenable logical drives disabled. Select drive. "F2" to accept data loss and to reenable logical drives. Fixed Disk Parameter Extended BIOS data Contact your service Table or BIOS Error. area being corrupted provider. System Halted. IOCHECK Active, Slot X Defective board in Run Diagnostics. slot X Replace failed assembly as indicated. Bus Master Time-out Defective board in Run Diagnostics. Slot X slot X Replace failed assembly as indicated. Parity Check 2-System A RAM parity error Run Diagnostics. Board Memory. occurred. Replace failed assembly Parity Check 2-SIMM as indicated. Memory Modules B, C, D, E (Run System Configuration A configuration error Press F10 to run EISA Utility = "F10" key) occurred during POST. Configuration Utility. 1600-32-Bit Server Server Manager/R board Run Diagnostics. Manager/R Board Failure failure. Error code Replace failed assembly displays after error as indicated or contact message. your service provider. (RESUME = "F1" KEY) As indicated to Press the F1 key. continue.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

reconfigure the
COMPAQ IDA-2
without the Array
Accelerator.
---------------------------------------------------------------------------
Error Code
Probable Source
Action
of Problem
---------------------------------------------------------------------------
1797-Slot # Drive Array
Hard parity error
Array Accelerator is
- Array Accelerator Read
while reading data
disabled.
Error Occurred. Data
from posted writes
in Array Accelerator
memory.
has been lost. Array
Accelerator is disabled.
---------------------------------------------------------------------------
1798-Slot # Drive Array
Hard parity error
Array Accelerator
- Array Accelerator
while writing data to
is disabled.
Write Error Occurred.
posted writes memory.
Array Accelerator is
disabled.
---------------------------------------------------------------------------
1799-Slot # Drive Array
Volume failed due to
Press F1 to continue
- Drive(s) Disabled due
loss of data in
with logical drives
to Array Accelerator
posted-writes memory.
disabled or F2 to
Data Loss. Select "F1"
accept data loss and
to continue with logical
reenable logical
drives disabled. Select
drive.
"F2" to accept data loss
and to reenable logical
drives.
---------------------------------------------------------------------------
Fixed Disk Parameter
Extended BIOS data
Contact your service
Table or BIOS Error.
area being corrupted
provider.
System Halted.
---------------------------------------------------------------------------
IOCHECK Active, Slot X
Defective board in
Run Diagnostics.
slot X
Replace failed assembly
as indicated.
---------------------------------------------------------------------------
Bus Master Time-out
Defective board in
Run Diagnostics.
Slot X
slot X
Replace failed assembly
as indicated.
---------------------------------------------------------------------------
Parity Check 2-System
A RAM parity error
Run Diagnostics.
Board Memory.
occurred.
Replace failed assembly
Parity Check 2-SIMM
as indicated.
Memory Modules B, C, D, E
---------------------------------------------------------------------------
(Run System Configuration A configuration error
Press F10 to run EISA
Utility = "F10" key)
occurred during POST.
Configuration Utility.
---------------------------------------------------------------------------
1600-32-Bit Server
Server Manager/R board Run Diagnostics.
Manager/R Board Failure
failure. Error code
Replace failed assembly
displays after error
as indicated or contact
message.
your service provider.
---------------------------------------------------------------------------
(RESUME = "F1" KEY)
As indicated to
Press the F1 key.
continue.
===========================================================================