Dell MXG610s Fibre Channel Switch Module Installation Guide May 2018 - Page 36

Table 11. Management port, Table 12. LEDs, Table 13. Weight and physical dimension

Page 36 highlights

Internal port: F_port / Server port 15 16 Table 11. Management port System components Console port Ethernet port Table 12. LEDs System components Module power and status LED Module identification LED FC port status and fault LEDs External port: N_port / Fabric port 30 31 HBA Mezzanine Port Lane 1 of Server Sled 7 Lane 1 of Server Sled 8 Description Micro-USB; external front panel Internal backplane Description One bicolor I/O module power and status LED at the right; upper side. One blue I/O module identification LED at the right; lower side. One bicolor port status; green/amber, LED above each SFP+ FC port. Four bicolor port status; green/amber, LED above each QSFP port. Table 13. Weight and physical dimension Height Width .75 cm 21.45 cm 1.08 in 8.44 in Depth 24.10 cm 9.49 in Weight-empty 1.35 kg 2.98 lb Weight-fully loaded 1.61 kg 3.55 lb Table 14. Environmental requirements Condition Ambient temperature Relative humidity, noncondensing Altitude, above sea level Shock Vibration Airflow Operational -5°C to 50°C (23°F to 122°F) 5% to 95% Up to 3200 m (10,000 feet) 10.0 G for 11 ms, half-sine wave Storage -40°C to 70°C (-40°F to 158°F) 5% to 95% (Non-condensing) 0 to 12192 m (40,000 feet) Half Sine Shock: 105 G for 2ms Square Wave Shock: 32 G with velocity change of 270 in/sec squared Trapezoidal wave shock: 70 G for 12ms Random Vibration: 0.4 Grms at 5-500 Hz for Random Vibration:1.88 Grms at 10-500 Hz 60 minutes/axis for 15 minutes/axis Sine Vibration: 1G at 5-500-5 Hz for 15 minutes/axis Sine Vibration:2.4 Grms at 5.9-500 Hz for 15 minutes/axis Maximum: 10.0 cfm N/A 36 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45

Internal port: F_port / Server port
External port: N_port / Fabric port
HBA Mezzanine Port
15
30
Lane 1 of Server Sled 7
16
31
Lane 1 of Server Sled 8
Table 11. Management port
System components
Description
Console port
Micro-USB; external front panel
Ethernet port
Internal backplane
Table 12. LEDs
System components
Description
Module power and status LED
One bicolor I/O module power and status LED at the right; upper
side.
Module
identification
LED
One blue I/O module
identification
LED at the right; lower side.
FC port status and fault LEDs
One bicolor port status; green/amber, LED above each SFP+ FC
port.
Four bicolor port status; green/amber, LED above each QSFP port.
Table 13. Weight and physical dimension
Height
Width
Depth
Weight—empty
Weight—fully loaded
.75 cm
1.08 in
21.45 cm
8.44 in
24.10 cm
9.49 in
1.35 kg
2.98 lb
1.61 kg
3.55 lb
Table 14. Environmental requirements
Condition
Operational
Storage
Ambient temperature
-5°C to 50°C (23°F to 122°F)
-40°C to 70°C (-40°F to 158°F)
Relative humidity, noncondensing
5% to 95%
5% to 95% (Non-condensing)
Altitude, above sea level
Up to 3200 m (10,000 feet)
0 to 12192 m (40,000 feet)
Shock
10.0 G for 11 ms, half-sine wave
Half Sine Shock: 105 G for 2ms
Square Wave Shock: 32 G with velocity
change of 270 in/sec squared
Trapezoidal wave shock: 70 G for 12ms
Vibration
Random Vibration: 0.4 Grms at 5-500 Hz for
60 minutes/axis
Sine Vibration: 1G at 5-500-5 Hz for 15
minutes/axis
Random Vibration:1.88 Grms at 10-500 Hz
for 15 minutes/axis
Sine Vibration:2.4 Grms at 5.9-500 Hz for 15
minutes/axis
Airflow
Maximum: 10.0 cfm
N/A
36
Technical
specifications