Dell PowerEdge M620 Hardware Owner's Manual - Page 108
E161C Power Supply
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Table 1-26. LCD Status Messages (continued) Code Text Cause Corrective Actions E1618 Predictive failure on Power Supply # (### W). Check PSU. Specified power supply has See "Troubleshooting detected a condition that Power Supply Modules" may predict a future power- on page 314. down event, such as an over-temperature warning or PSU communication error, that could develop into a fault condition in the power supply. E161C Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is Check the AC power attached to the system, but source for the specified it has lost its AC input. power supply. If the problem persists, see "Troubleshooting Power Supply Modules" on page 314. E1620 Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's AC input is outside of the allowable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supply Modules" on page 314. E1624 Lost power supply redundancy. Check PSU cables. The power supply See "Troubleshooting subsystem is no longer Power Supply Modules" redundant. If the remaining on page 314. power supply fails, the system shuts down. E1626 Power Supply The power supplies in the Mismatch. system are not the same PSU1 = ### W, wattage. PSU2 = ### W. Ensure that power supplies with matching wattage are installed. See the Technical Specifications outlined in your system's Getting Started Guide. 108 About Your System