Table 1-27. Blade Messages (continued) Message Causes Corrective Actions Memory tests terminated by keystroke. The spacebar or ESC key was pressed during POST to terminate the memory test. Information only. Keyboard data line failure. Keyboard stuck key failure. Keyboard cable connector Ensure that the keyboard is loose or improperly properly connected. If the connected. Keyboard or problem persists, see keyboard/mouse controller "Getting Help" on page 361. may be faulty. Keyboard fuse has Overcurrent detected in See "Getting Help" on failed. the keyboard connector. page 361. No boot device available. Faulty or missing diskette Check the Integrated drive, optical drive, or hard Devices configuration drive. settings in the System Setup program and ensure that the controller for the boot device is enabled. See "Using the System Setup Program and UEFI Boot Manager" on page 137. Ensure that the controller for the boot device is enabled. If the problem persists, replace the drive. See "Hard Drives" on page 267. No boot sector on hard-disk drive. An operating system is not Check the hard-drive on the hard drive. configuration settings in the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on page 137. No timer tick interrupt. Faulty blade board. See "Getting Help" on page 361. Not a boot diskette. Not a bootable diskette. Use a bootable diskette. 128 About Your System