Dell PowerEdge R760 Installation and Service Manual - Page 133
Table 89. 8 x 2.5-inch NVMe RAID with fPERC H965i
View all Dell PowerEdge R760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 133 highlights
Figure 86. Configuration 10: 8 x 2.5-inch NVMe RAID with fPERC (H965i) NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 89. 8 x 2.5-inch NVMe RAID with fPERC (H965i) Order From 1 SL4_CPU1_PB2 (signal connector on system board) 2 SL3_CPU1_PA2 (signal connector on system board) 3 SIG_PWR_1 (system board power connector) 4 CTRL_SRC_PB1 (fPERC controller connector) 5 CTRL_SRC_PA1 (fPERC controller connector) To CTRL_DST_PB1 (fPERC input connector) CTRL_DST_PA1 (fPERC input connector) BP_PWR_1 (backplane power connector) BP_DST_PA2 (backplane signal connector) and BP_DST_PB2 (backplane signal connector) BP_DST_PA1 (backplane signal connector) and BP_DST_PB1 (backplane signal connector) NOTE: An 8 x 2.5-inch NVMe backplane with fPERC H965i should be assembled outside and inserted into the system, along with all necessary cables. Installing and removing system components 133