Dell PowerEdge R760 Installation and Service Manual - Page 172
PERC module, Removing the rear mounting front PERC module
![]() |
View all Dell PowerEdge R760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 172 highlights
Figure 126. Configuration 50: BOSS-N1 module in 4 x 2.5-inch rear drive module NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order. Table 129. BOSS-N1 module in 4 x 2.5-inch rear drive module Order From 1 BOSS_PWR_MB (BOSS power connector on system board) 2 SL12_PCH_PA6 (signal connector on system board) To BOSS_PWR (BOSS module power connector) BOSS (BOSS module signal connector) NOTE: The BOSS-N1 signal cable is routed beneath rear drive module and ensure not to damage the cable. PERC module This is a service technician replaceable part only. Removing the rear mounting front PERC module Prerequisites 1. Follow the safety guidelines listed in the Safety instructions. 2. Follow the procedure listed in the Before working inside your system. 3. Remove the cooling fan cage assembly. 4. Remove the drive backplane cover. 5. If required, remove the air shroud or remove the GPU air shroud.. 6. Disconnect all the cables, observe the cable routing. NOTE: Refer to cable routing section for more information. Steps 1. Using a Phillips #2 screwdriver, loosen the captive screws on the rear mounting front PERC module. 172 Installing and removing system components
![](/manual_guide/products/dell-poweredge-r760-installation-service-manual-8c03f25/172.png)