Dell PowerVault 130T DLT Service Manual - Page 27

TIP 1010: Library Power Problems

Page 27 highlights

PowerVault 130T Service Manual TIP 1010: Library Power Problems TIP 1010: Library Power Problems Use this TIP to troubleshoot and repair power problems with the library. Symptom Explanation The library does not power on. Conditions That Could Cause This Problem Electronics module is faulty. Power cable connection is loose or faulty. Faulty library power switch. Customer supplied power is missing. WARNING: Observe the safety precautions in "About This Manual" when working with voltage in the PowerVault 130T Library, and with input line voltage. 1. Is the power switch on? Yes: Go to step 2. No: Turn on the power switch. 2. Is the power cable properly seated in the library and in the input? Yes: Go to step 3. No: Turn off power switch. Reseat the AC power cable connector at the back of the library and at the AC wall outlet. Turn on power switch. 3. Is the customer's input power circuit breaker on? Yes: Go to step 4. No: Reset the circuit breaker. 4. Are the library fans turning? Yes: Go to step 5. No: Replace the electronics module. 5. Are all of the connectors on the CYC card seated? Yes: Go to step 6. No: Seat the connectors. 6. Are there any displays or LEDS Yes: Go to step 7. on the operator panel? No: Replace the operator panel. 7. Place a service call. 4473D 2-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

PowerVault 130T Service Manual
TIP 1010: Library Power Problems
4473D
2–5
TIP 1010: Library Power Problems
Use this TIP to troubleshoot and repair power problems with the library.
Symptom Explanation
Conditions That Could Cause This Problem
The library does not power on.
S
Electronics module is faulty.
S
Power cable connection is loose or faulty.
S
Faulty library power switch.
S
Customer supplied power is missing.
WARNING:
Observe the safety precautions in “About This Manual”
when working with voltage in the PowerVault 130T Library, and with
input line voltage.
1.
Is the power switch on?
Yes:
Go to step
2.
No:
Turn on the power switch.
2.
Is the power cable properly seated
in the library and in the input?
Yes:
Go to step
3.
No:
Turn off power switch.
Reseat the AC power cable
connector at the back of the library and at the AC wall
outlet.
Turn on power switch.
3.
Is the customer’s input power
circuit breaker on?
Yes:
Go to step
4.
No:
Reset the circuit breaker.
4.
Are the library fans turning?
Yes:
Go to step 5.
No:
Replace the electronics module.
5.
Are all of the connectors on the
CYC card seated?
Yes:
Go to step
6.
No:
Seat the connectors.
6.
Are there any displays or LEDS
on the operator panel?
Yes:
Go to step 7.
No:
Replace the operator panel.
7.
Place a service call.