Epson BrightLink 436Wi Installation Guide - Page 33
Attach the arm cover, Turn on the projector and check the screen, A/V Mute
View all Epson BrightLink 436Wi manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
English 12. Attach the arm cover Secure the arm cover with a hexagonal wrench (M4) and an M4 × 12 mm hexagon socket head cap bolt. M4 × 12 mm hexagon socket head cap bolt Arm cover 13. Turn on the projector and check the screen 1. Plug in and turn on the projector. 2. Hold down the A/V Mute button on the remote control for five seconds to flip the image top-to-bottom. 3. Loosen the screws on the adjustment unit (A, B, C, and D) as shown below to adjust the screen position. 4. Adjust the vertical angle of the arm using screw (E) on the bottom of the arm plate. The arm rises when you tighten the screw, and lowers when you loosen it. A: Vertical tilt adjustment: 0 to -9.5° B: Horizontal roll adjustment: 0 to ± 5° C: Horizontal rotation adjustment: 0 to ± 5° D: Horizontal slide adjustment: 0 to ± 1.8 inches (0 to ± 45 mm) E: Vertical angle adjustment screw: 0 to 5.3 inches (0 to 134 mm) (arm length minimum) 0 to 9.1 inches (0 to 230 mm) (arm length maximum) Arm plate Adjustment unit 33