Specifications of Interface and Connector, RS-232 Serial Interface
View all Epson TM-m50II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
Specifications of Interface and Connector Appendix RS-232 Serial Interface Interface board specifications (RS-232-compliant) Item Data transfer method Synchronization Handshake Signal level Bit length MARK SPACE Transmission speed Parity Stop bit Connector Specifications Serial Asynchronous Can be set using the commands, software settings mode, or TM-m50II Utility. • DTR/DSR control • XON/XOFF control -3 to -15 V logic "1"/OFF +3 to +15 V logic "0"/ON Can be set using the commands, software settings mode, or TM-m50II Utility. • 7 bit • 8 bit Can be set using the commands, software settings mode, or TM-m50II Utility. 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps [bps: bits per second] Can be set using the commands, software settings mode, or TM-m50II Utility. • No parity • Even parity • Odd parity 1 bit or more However, the stop bit is fixed to 1 bit when transfer data is sent from the printer. D-Sub 9 pin (male) connector 112