Epson TM-m50II Technical Reference Guide - Page 114

XON/XOFF, Signal, Printer status, Condition for BUSY, Receive buffer full, Offline

Page 114 highlights

Appendix XON/XOFF When XON/XOFF control is selected, the printer transmits the XON or XOFF signals as follows. The timing of the transmission varies depending on the conditions configured as BUSY. Signal Printer status Condition for BUSY Receive buffer full Receive buffer full/ Offline XON When the printer goes online after it is turned on (or Transmit after it is reset using the interface) Transmit When the receive buffer is released from the buffer Transmit full state Transmit When the printer switches from offline to online - Transmit When the printer recovers from an error using some ESC/POS commands Transmit XOFF When the receive buffer becomes full Transmit Transmit When the printer switches from online to offline - Transmit Code The hexadecimal numbers corresponding to the XON/XOFF codes are shown below. • XON code: 11H • XOFF code: 13H 114

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

114
Appendix
XON/XOFF
When XON/XOFF control is selected, the printer transmits the XON or XOFF signals as follows.
The timing of the transmission varies depending on the conditions configured as BUSY.
Code
The hexadecimal numbers corresponding to the XON/XOFF codes are shown below.
XON code: 11H
XOFF code: 13H
Signal
Printer status
Condition for BUSY
Receive buffer full
Receive buffer full/
Offline
XON
When the printer goes online after it is turned on (or
after it is reset using the interface)
Transmit
Transmit
When the receive buffer is released from the buffer
full state
Transmit
Transmit
When the printer switches from offline to online
-
Transmit
When the printer recovers from an error using some
ESC/POS commands
-
Transmit
XOFF
When the receive buffer becomes full
Transmit
Transmit
When the printer switches from online to offline
-
Transmit