Hayward HLPRO4 OmniPL-Automation-Operation-Manual-092786RevD - Page 18

pH Dispense, pH Dispense Control Screen

Page 18 highlights

NOTE: If a conventional or solar heater is operating, it is likely that the temperature of the water at the cell is higher than the pool/spa water temperature displayed on the OmniPL default display. Restart Average Salt - The OmniPL monitors salt level while chlorinating. At any time, go to the chlorinator diagnostic screen to view the average salt based on an ongoing calculated average. If you restart average salt, the previous average is deleted and the OmniPL begins calculating the new average from that moment. The OmniPL will start with the instant salt reading and calculate an ongoing average. Reverse Polarity - The OmniPL periodically reverses the polarity of the voltage applied to the chlorinator cell in order to automatically clean off any calcium deposits. To check operation in both polarities, touch this button. The chlorinator will turn off, wait for 15 seconds and then turn on in the opposite polarity. Reset Cell Maintenance Timer - To maintain maximum performance, it is recommended that you open and visually inspect the chlorinator cell every 3 months or after cleaning your filter. The OmniPL will remind you to do this by displaying a message to clean and inspect the cell after approximately 500 hours of operation. You can restart the timer by touching this button. pH Dispense If using an HL-CHEM: The Hayward HL-CHEM Sense and Dispense accessory continuously tests the pool's sanitization and pH levels allowing the OmniPL to automatically generate the correct amount of chlorine and dispense the proper amount of pH reducer. Refer to the information below as well as the HL-CHEM manual for configuration and operation instructions. 1 / 2 ON Dispensing On vsp pH alarm light row 7.3 7.3 heat/cool cleaner POOL features uclights chlorinator pH Dispense Control Screen Enable / Disable Slide this switch to enable and disable the pH dispenser and then touch the Save button. Current pH Level Shows the current pH reading in the pool or spa. 17 Set pH Level - Set the desired pH level. ON 7.3 Dispensing On 7.3 Calibrate - Calibrate the pH reading if the OmniPL doesn't display the correct level. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
17
NOTE: If a conventional or solar heater is operating, it is likely that the temperature of the water at the
cell is higher than the pool/spa water temperature displayed on the OmniPL default display.
Restart Average Salt -
The OmniPL monitors salt level while chlorinating.
At any time, go to the
chlorinator diagnostic screen to view the average salt based on an ongoing calculated average.
If
you restart average salt, the previous average is deleted and the OmniPL begins calculating the new
average from that moment.
The OmniPL will start with the instant salt reading and calculate an
ongoing average.
Reverse Polarity
- The OmniPL periodically reverses the polarity of the voltage applied to the chlo-
rinator cell in order to automatically clean off any calcium deposits.
To check operation in both
polarities, touch this button.
The chlorinator will turn off, wait for 15 seconds and then turn on in the
opposite polarity.
Reset Cell Maintenance Timer
- To maintain maximum performance, it is recommended that you
open and visually inspect the chlorinator cell every 3 months or after cleaning your filter.
The OmniPL
will remind you to do this by displaying a message to clean and inspect the cell after approximately
500 hours of operation.
You can restart the timer by touching this button.
pH Dispense
If using an HL-CHEM:
The Hayward HL-CHEM Sense and Dispense accessory continuously tests
the pool’s sanitization and pH levels allowing the OmniPL to automatically generate the correct
amount of chlorine and dispense the proper amount of pH reducer.
Refer to the information below
as well as the HL-CHEM manual for configuration and operation instructions.
uc
lights
chlorinator
alarm
pH
POOL
features
1 / 2
vsp
heat/cool
cleaner
light row
pH Dispense Control Screen
ON
Dispensing On
7.3
7.3
ON
Dispensing On
7.3
7.3
Set pH Level
- Set the
desired pH level.
Calibrate
- Calibrate
the pH reading if the
OmniPL doesn’t dis-
play the correct level.
Enable / Disable
-
Slide this switch to
enable and disable the
pH dispenser and then
touch the Save button.
Current pH Level
-
Shows the current pH
reading in the pool or
spa.