POST Error Messages Code/Message 6911-System Board CPU Subsystem Failure Detected Health LED Red 6912-System Board Voltage Red Regulator Failure Detected 6913-System Board Main Red Voltage Failure Detected 6914-Forced System Green Shutdown from an over-temp fault condition on previous boot 6915-CPU not detected on previous attempt to boot. 6916-CPU Heatsink not properly attached Green Amber 6918-System Real Time Clock Oscillator not running within tolerance. Amber 6919-Temperature and Power Red Monitoring Hardware failure Possible Cause Recommended Action Processor has failed. ● ● Potential enclosure or ● blade PC issue. ● ● Potential enclosure or ● blade PC issue. ● ● Internal temperature ● exceeds specification. ● ● Clear CMOS. Replace the blade PC. Swap the blade PC to a different bay in the enclosure and retest. Put the blade PC into a different enclosure. If the blade PC works in a different enclosure, troubleshoot the original enclosure. For troubleshooting information, see Troubleshooting on page 49. Replace the blade. Swap the blade PC to a different bay in the enclosure and retest. Put the blade PC into a different enclosure. If the blade PC works in a different enclosure, troubleshoot the original enclosure. For troubleshooting information, see Troubleshooting on page 49. Replace the blade. Ensure that the system fans are functioning properly and that the enclosure has adequate ventilation. Check the processor heatsink. Replace the blade PC. The CPU was not detected on previous boot attempt. Informational message only. The heatsink is loose. ● Remove the blade PC and check if heatsink is loose or not present. Tighten CPU heatsink screws to 8 inch-lbs of tension. ● Replace the blade PC if the messages persist. System Real Time Clock Oscillator not running within tolerance. ● Replace CMOS battery. ● If the problem persists, replace the blade PC. Blade PC failure. Replace the blade PC. 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79

POST Error Messages
Code/Message
Health LED
Possible Cause
Recommended Action
6911-System Board CPU
Subsystem Failure Detected
Red
Processor has failed.
Clear CMOS.
Replace the blade PC.
6912-System Board Voltage
Regulator Failure Detected
Red
Potential enclosure or
blade PC issue.
Swap the blade PC to a different bay in the
enclosure and retest.
Put the blade PC into a different enclosure.
If the blade PC works in a different
enclosure, troubleshoot the original
enclosure. For troubleshooting information,
see
Troubleshooting
on page
49
.
Replace the blade.
6913-System Board Main
Voltage Failure Detected
Red
Potential enclosure or
blade PC issue.
Swap the blade PC to a different bay in the
enclosure and retest.
Put the blade PC into a different enclosure.
If the blade PC works in a different
enclosure, troubleshoot the original
enclosure. For troubleshooting information,
see
Troubleshooting
on page
49
.
Replace the blade.
6914-Forced System
Shutdown from an over-temp
fault condition on previous boot
Green
Internal temperature
exceeds specification.
Ensure that the system fans are functioning
properly and that the enclosure has
adequate ventilation.
Check the processor heatsink.
Replace the blade PC.
6915-CPU not detected on
previous attempt to boot.
Green
The CPU was not
detected on previous
boot attempt.
Informational message only.
6916-CPU Heatsink not
properly attached
Amber
The heatsink is loose.
Remove the blade PC and check if
heatsink is loose or not present. Tighten
CPU heatsink screws to 8 inch-lbs of
tension.
Replace the blade PC if the messages
persist.
6918-System Real Time Clock
Oscillator not running within
tolerance.
Amber
System Real Time
Clock Oscillator not
running within
tolerance.
Replace CMOS battery.
If the problem persists, replace the blade
PC.
6919-Temperature and Power
Monitoring Hardware failure
Red
Blade PC failure.
Replace the blade PC.
47