HP BladeSystem PC Blade Enclosure G2., BIOS 3.xx introduces BIOS BMC Firmware
View all HP BladeSystem bc2800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
POST Error Messages Code/Message 6920-Processor in ForceThrottle Mode Health LED Amber 6921-Blade System Management Controller firmware update failed Amber 6922-Blade temperature Amber detected to be below 0 degrees Celsius 6923-CPU Temperature Red Monitoring Hardware failure 6924-Graphics Temperature Red Monitoring Hardware failure 6925-Blade/Enclosure Communication error Amber 6927-Previous POST under Recovery BIOS. 6928-POST under Recovery BIOS image. Green Amber 6929- Blade performance is reduced due to insufficient enclosure power and/or cooling. Amber 6931-BIOS unable to update Red BMC Primary Firmware Possible Cause Enclosure or environmental issue. The flashing process was interrupted. Recommended Action ● Ensure the enclosure health LED is green and health status is OK. If LED not green, troubleshoot the enclosure. For troubleshooting information, see Troubleshooting on page 49. ● If the enclosure health LED is green, check heatsink installation and operating ambient. Make sure every enclosure slot is filled with a blank or a blade PC. Re-flash the BMC firmware image. The blade PC is operating in temperatures below specification. Check operating ambient. Operate the blade PC within environmental specifications. CPU temperature monitoring hardware has failed. Replace the blade PC. System graphics temperature monitoring hardware has failed. Replace the blade PC. Potential enclosure or ● Swap the blade PC to a different bay in the blade PC issue. enclosure and retest. ● Put the blade PC into a different enclosure. If the blade PC works in a different enclosure, troubleshoot the original enclosure. For troubleshooting information, see Troubleshooting on page 49. ● Replace the blade. Previous POST under Informational message only. Recovery BIOS. POST under Recovery ● BIOS image. ● Re-flash the BIOS. If the problem persists, replace the blade PC. Blade was a bc2800 and inserted into an enclosure that cannot support full processor performance. Power off blade and remove blade, or update enclosure Integrated Administrator firmware to version 4.30 or greater, or update enclosure to HP BladeSystem PC Blade Enclosure G2. Three consecutive attempts to update the BMC firmware failed during POST. BIOS 3.xx introduces BIOS BMC Firmware Updating. This feature links the BIOS version to the BMC firmware version. The BMC firmware is updated during BIOS POST. BIOS will attempt to update the BMC firmware 3 times before booting to an OS without successfully updating the BMC firmware. 48 Chapter 6 POST Error Messages