HP Carrier-grade cc3300 UserÆs Guide and Technical UserÆs Gu - Page 37

Server Management Summary

Page 37 highlights

Server Management Summary The server management system features a Board Management Controller (BMC), which autonomously monitors server status and provides the interface to server management control functions. This controller is responsible for controlling system power, resets, monitoring voltages, temperatures, fans, and communicating with secondary controllers on its Intelligent Platform Management Bus (IPMB). Detailed server management tool information and supported operating system information is contained in the Intel Server Control Installation (ISC) Guide For the cc2300 & cc3300 Carrier Grade Server. ISC is a server management tool that provides real time monitoring and alerting for server hardware, emergency remote management and remote server setup. The functions of each controller are summarized in the following sections. Board Management Controller (BMC) The BMC on the server board provides server management monitoring capabilities. Associated with the BMC is a flash memory that holds the operational code, sensor data records (SDR), and system event log (SEL). A serial EEPROM holds the BMC configuration defaults and field replaceable unit (FRU) information. The BMC supports the following: • Server board voltage monitoring • Fan failure detection • Fan speed control • Processor voltage monitoring • Processor presence detection • Processor internal error (IERR) monitoring • Fault resilient booting (FRB) • Processor disable control • Watchdog timer • Periodic system management interrupt (SMI) timer • I2C master controller for the Intelligent Platform Management Bus (IPMB) • Three private I2C management bus interfaces • Server management software (SMS) and server management mode (SMM) IPMB message receiver • Event message receiver • System event log (SEL) management and access • Sensor data record (SDR) repository management and access • Processor nonmaskable interrupt (NMI) monitoring • Processor SMI monitoring • Time-stamp clock • Secure mode • Software front panel NMI generation cc2300 Carrier Grade Server Product Guide 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

cc2300 Carrier Grade Server Product Guide
37
Server Management Summary
The server management system features a Board Management Controller (BMC), which
autonomously monitors server status and provides the interface to server management control
functions.
This controller is responsible for controlling system power, resets, monitoring voltages,
temperatures, fans, and communicating with secondary controllers on its Intelligent Platform
Management Bus (IPMB).
Detailed server management tool information and supported operating system information is
contained in the Intel Server Control Installation (ISC) Guide For the cc2300 & cc3300 Carrier
Grade Server. ISC is a server management tool that provides real time monitoring and alerting for
server hardware, emergency remote management and remote server setup.
The functions of each controller are summarized in the following sections.
Board Management Controller (BMC)
The BMC on the server board provides server management monitoring capabilities.
Associated
with the BMC is a flash memory that holds the operational code, sensor data records (SDR), and
system event log (SEL).
A serial EEPROM holds the BMC configuration defaults and field
replaceable unit (FRU) information.
The BMC supports the following:
Server board voltage monitoring
Fan failure detection
Fan speed control
Processor voltage monitoring
Processor presence detection
Processor internal error (IERR) monitoring
Fault resilient booting (FRB)
Processor disable control
Watchdog timer
Periodic system management interrupt (SMI) timer
I
2
C master controller for the Intelligent Platform Management Bus (IPMB)
Three private I
2
C management bus interfaces
Server management software (SMS) and server management mode (SMM) IPMB message
receiver
Event message receiver
System event log (SEL) management and access
Sensor data record (SDR) repository management and access
Processor nonmaskable interrupt (NMI) monitoring
Processor SMI monitoring
Time-stamp clock
Secure mode
Software front panel NMI generation