HP Cisco Catalyst Blade Switch 3020 Using HP Smart Update Manager with HP Inte - Page 16

HP SUM 6.0.0 and later Instructions, After confirming the updates to be performed

Page 16 highlights

HP SUM 6.0.0 and later Instructions 1) Start with systems powered on and running HP-UX. 2) Start HP SUM from the Integrity platform bundle location. o The current directory will be added as a baseline automatically. 3) Go to the Nodes page and select 'Add Node'. o Enter IP address and administrator credentials for the system iLO. 4) After the node completes validating the system type, select 'Inventory' from the Action menu. o Select the current directory as the Baseline to apply to the node. 5) After Inventory completes on all the nodes, select 'Reports' from the Action menu and run the Installable Details report and review. o You can select multiple nodes to run the report on at once using ctrl-click on the node names in the list on the left of the nodes page and then using the 'Generate Report' button. o This report provides a full view of all the recommended updates that HP SUM would apply to the selected node when you continue. 6) After confirming the updates to be performed, select 'Deploy' from the Action menu on the iLO node. o Set Reboot option to 'If Needed' or 'Always' using the drop down menu. o Click the 'Analyze' button to have HP SUM confirm the changes. o Click the 'Deploy' button to start the update process. 7) After the iLO node finishes updating add the HP-UX node using 'Add Node'. o Enter the IP address or DNS name and root credentials for the HP-UX instance. 8) Run Inventory on the HP-UX node o Select the current directory for the Baseline to be applied to the node. 9) After Inventory completes, select 'Reports' from the Action menu and run the Updates to be Installed report on the HP-UX nodes and review. o This report provides a full view of all the recommended updates that HP SUM would apply to the selected node when you continue. 10) Start Deploy on the HP-UX node. o Be sure to set the Reboot option to 'If Needed' or 'Always' in order to fully activate any I/O FW updates that may require a reboot. 11) After HP SUM completes updates on the HP-UX node and the systems have finished rebooting, you can continue with other updates not controlled by HP SUM. o On non-HP-UX systems, EFI packages can be used for updating I/O cards. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

HP SUM 6.0.0 and later Instructions
1)
Start with systems powered on and running HP-UX.
2)
Start HP SUM from the Integrity platform bundle location.
o
The current directory will be added as a baseline automatically.
3)
Go to the Nodes page and select ‘Add Node’.
o
Enter IP address and administrator credentials for the system iLO.
4)
After the node completes validating the system type, select ‘Inventory’ from the Action menu.
o
Select the current directory as the Baseline to apply to the node.
5)
After Inventory completes on all the nodes, select ‘Reports’ from the Action menu and run the
Installable Details
report and review.
o
You can select multiple nodes to run the report on at once using ctrl-click on the node
names in the list on the left of the nodes page and then using the ‘Generate Report’ button.
o
This report provides a full view of all the recommended updates that HP SUM would apply
to the selected node when you continue.
6)
After confirming the updates to be performed, select ‘Deploy’ from the Action menu on the iLO
node.
o
Set Reboot option to ‘If Needed’ or ‘Always’ using the drop down menu.
o
Click the ‘Analyze’ button to have HP SUM confirm the changes.
o
Click the ‘Deploy’ button to start the update process.
7)
After the iLO node finishes updating add the HP-UX node using ‘Add Node’.
o
Enter the IP address or DNS name and root credentials for the HP-UX instance.
8)
Run Inventory on the HP-UX node
o
Select the current directory for the Baseline to be applied to the node.
9)
After Inventory completes, select ‘Reports’ from the Action menu and run the
Updates to be
Installed
report on the HP-UX nodes and review.
o
This report provides a full view of all the recommended updates that HP SUM would apply
to the selected node when you continue.
10)
Start Deploy on the HP-UX node.
o
Be sure to set the Reboot option to ‘If Needed’ or ‘Always’ in order to fully activate any I/O
FW updates that may require a reboot.
11)
After HP SUM completes updates on the HP-UX node and the systems have finished rebooting, you
can continue with other updates not controlled by HP SUM.
o
On non-HP-UX systems, EFI packages can be used for updating I/O cards.
16