HP Indigo WS6600 Splice Detection System Installation and Troubleshooting -- C - Page 41

Troubleshooting, Sensor does not turn on, Follow these steps when the sensor does not turn on.

Page 41 highlights

4 Troubleshooting It explains troubleshooting. NOTE: The press needs to be properly leveled and aligned. Poor leveling and alignment will lead to false detections by the splice detector. For all the troubleshooting procedures below ● The following is the molex connector in the bridge: ● The following is the molex connector in the electronics cabinet: Sensor does not turn on Follow these steps when the sensor does not turn on. 1. Open the bridge door and examine the splice detector molex connectors: ● Verify that pin 4 (brown) and pin 5 (blue) are not loose. If they are loose, secure them. Troubleshooting 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Troubleshooting
4
It explains troubleshooting.
NOTE:
The press needs to be properly leveled and aligned. Poor leveling and alignment will lead to
false detections by the splice detector.
For all the troubleshooting procedures below
The following is the molex connector in the bridge:
The following is the molex connector in the electronics cabinet:
Sensor does not turn on
Follow these steps when the sensor does not turn on.
1.
Open the bridge door and examine the splice detector molex connectors:
Verify that pin 4 (brown) and pin 5 (blue) are not loose. If they are loose, secure them.
Troubleshooting
39