HP Indigo WS6600 Splice Detection System Installation and Troubleshooting -- C - Page 6
Installation procedures, Preliminary steps
View all HP Indigo WS6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
2 Installation procedures It explains the installation procedure. NOTE: Before installing, check that the press is properly leveled and aligned. Poor leveling and alignment will lead to false detections by the splice detector. The splice detection assembly is installed in the press bridge that is between the ILP (if installed) and the engine input, or between the unwinder (if ILP not installed) and the engine input: 1 Engine input 2 ILP 3 Unwinder 4 Press bridge Preliminary steps Follow these steps for preliminary steps. 1. Using an M6 Allen screw, install the small rear holder bracket (CA344-35880) onto the rear holder bracket (CA344-35890). 1 Rear holder bracket 2 Rear ground bar 4 Chapter 2 Installation procedures
Installation procedures
2
It explains the installation procedure.
NOTE:
Before installing, check that the press is properly leveled and aligned. Poor leveling and
alignment will lead to false detections by the splice detector.
The splice detection assembly is installed in the press bridge that is between the ILP (if installed) and the
engine input, or between the unwinder (if ILP not installed) and the engine input:
1
Engine input
3
Unwinder
2
ILP
4
Press bridge
Preliminary steps
Follow these steps for preliminary steps.
1.
Using an M6 Allen screw, install the small rear holder bracket (CA344-35880) onto the rear holder
bracket (CA344-35890).
1
Rear holder bracket
2
Rear ground bar
4
Chapter 2