HP LH4r HP Netserver LC 3 NetRAID Installation Guide

HP LH4r - NetServer - 256 MB RAM Manual

HP LH4r manual content summary:

  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 1
    information specific to your cluster configuration that you will need during the installation of your cluster. • HP NetServer Microsoft Cluster Installation Guide - This is the first of two documents used to install the cluster. It covers the installation of all cluster supported HP NetServers and
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 2
    This later version incorporates technical, grammatical and format changes along with adding installation instructions for additional HP NetServers. Revised the Configuration Guide to add: "Logical Disks - 1 per RAID array" to Shared Storage "6 maximum per NetRAID adapter" to Logical Disks in Shared
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 3
    Power source System software: Navigator version Operating System Service pack SPU Model Clock speed No. of CPUs HP NetServer LC3 Each node must be the same model SPU, but may have different size main memory and cache. 2 HP Storage System/6 with HP NetRAID controller and HP disks. See Shared Storage
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 4
    may not be used for client communication. Client LAN Any LAN HP D5013A (10/100TX PCI) (or HP J3171A) 2.24.00.0000 or later 1 P4 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver If the NIC used is the same as the Intra-cluster
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 5
    arrays SPU internal drive bays or HP external drive cabinet (e.g., HP Storage System/6) Must be HP SPU embedded controller or any controller (any number, manufacturer or driver) in any available I/O slot (see SPU I/O slots above). Any HP cables that meet SCSI specifications and any SCSI bus speed
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 6
    HP Microsoft Cluster Server with One HP NetRAID Adapter 4
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 7
    HP NetServer Microsoft Cluster Installation Guide with Shared Storage System Supplement NetRAID (Storage System/6, Rack Storage/8 and Rack Storage/12) HP AutoRAID Disk Array Model 12H or HP A3661B Model 30/FC High Availability Disk Array 8 March 1999
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 8
    associated instruction(s). Servicing Any service, adjustment, maintenance, or repair must be performed only by authorized service in this manual: • Microsoft Server Division 10955 Tantau Avenue Cupertino, CA 95014-0770, USA © Copyright 1999, Hewlett-Packard Company HP NetServer Installation Guide
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 9
    ASSIGNMENTS ...33 7 MICROSOFT CLUSTER SERVER SOFTWARE SETUP 35 INSTALL MSCS ON SYSTEM B...35 INSTALL MSCS ON SYSTEM A...39 INSTALL SERVICE PACK OR HOT FIX ...39 8 CLUSTER TESTING ...40 HARDWARE VERIFICATION AND LABELING UTILITY 40 CLUSTER INSTALLATION TEST...41 HP NetServer Installation Guide 3
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 10
    HP NetServers, set up, assemble and cable the cluster, and install server and cluster software. NOTE This installation guide is incomplete without the supplement specific to your shared storage system. When directed by this guide, turn to the supplement to get the necessary instructions. Version
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 11
    A Graphical Overview to Setting Up the Cluster CAUTION Departing from the sequence shown here may cause unnecessary work and unpredictable results. HP NetServer Installation Guide 5
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 12
    . 2. On the site navigator bar, select SEARCH, then search for Q147222 in the "Support & Knowledge Base" category. 3. On the Search Results page, select Group of Hotfixes for Exchange 5.5 and IIS 4.0, then follow the ftp path to download the "clusfixi.exe" file. HP NetServer Installation Guide 6
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 13
    Service Grounding Kit (3M® part number 8505, or equivalent). Need More Help? HP Information Assistant provides extensive support information and is available on the HP NetServer Online Documentation CD-ROM. Although you can access HP Information Assistant from the NetServer Navigator Main menu, HP
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 14
    to the Shared Storage Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster configuration for the HP NetServer PCI slots to use. See instructions supplied with the component or see part "2 NetServer Hardware Setup" of the Shared Storage Supplement for
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 15
    3 Shared Storage Hardware Setup part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement HP NetServer Installation Guide 9
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 16
    instructions in the shared storage supplement. In addition you should have rack layouts of your system printed from the HP NetServers Rack Assistant program. If not, see HP NetServers web site to download this program at: http://www.hp.com/netserver See the Configuration Guide for your cluster for
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 17
    the Microsoft Service Pack On page ... 11 12 13 14 16 18 20 22 24 25 27 LCII Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 18
    down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS is a newer version, choose Continue and go
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 19
    subnets. LH Pro 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS is
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 20
    LAN IP addresses must be on different subnets. LH 3 These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model allow the server to reboot. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator BIOS
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 21
    1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 22
    is complete, the D5013A NIC drivers must be manually set to the correct LAN speed Mbps. Do not use the Auto setting. LH 3 (with NetRAID Local and Shared Storage) server to reboot. The server boots from the CD and displays the Navigator Main menu. NOTE If prompted that the HP NetServer Navigator
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 23
    drivers you need. If you are using the embedded SCSI channels, load the Symbios driver at this time. 4. Continue the installation and select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system HP NetServer Installation Guide
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 24
    setting. LH 4 These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC shared storage solutions. Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 25
    .0 and exit Navigator to reboot the server. 2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver for the
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 26
    is complete, the D5013A NIC drivers must be manually set to the correct LAN speed setting. LPr These procedures provide instructions for servers using NetRAID and AutoRAID shared storage HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 27
    1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 28
    subnets. 4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN speed. Log on and from the System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server. 3. If you have special NetServer local SCSI bus options enter
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 29
    Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: 3. Load drivers , WINS Address, etc. at this time. HP NetServer Installation Guide 23
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 30
    Navigator CD, insert the first CD of the Microsoft Windows NT Server, Enterprise Edition, and exit Navigator to reboot the server. 2. Select the following options when prompted: • Choose the unpartitioned space and install Windows NT. • Choose NTFS file system HP NetServer Installation Guide
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 31
    8000 These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC shared storage solutions Configure NetServer Hardware and BIOS 1. Make sure you power down System A and power up System B. 2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 32
    server. 2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass storage drivers: • The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD. • First, load the driver the Auto setting. HP NetServer Installation Guide 26
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 33
    Pack for All HP NetServers Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service Pack (SP3 or SP4). Do not install the Hot Fix associated with Service Pack 3 at this time. NOTE Do not install the Microsoft Cluster Server Software (MSCS) at
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 34
    Storage Software Setup" in the Shared Storage Supplement Create the Array File Systems Use the instructions below and Windows NT Disk Administrator to partition, assign drive letters, and format the local (non-shared) disks followed by the shared disk arrays. HP NetServer Installation Guide 28
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 35
    disk in the partition (the default). In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary drive letter to the disk array. HP NetServer Installation Guide 29
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 36
    , Partitioned Disk Array NOTE Do not partition a disk into separate drives. Microsoft Cluster Server Software will only manage one partition per disk. 4. Repeat steps 1 through 3 to Administrator assigned the next sequential letter to the disk array. HP NetServer Installation Guide 30
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 37
    Letter. Disk Administrator displays the Assign Drive Letter dialog. 3. In the dialog, select a drive letter, and click OK. To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this guide uses drive letters X and Y. HP NetServer Installation Guide 31
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 38
    (name) for the drive. Choosing a descriptive label such as "Shared Drive X" will be helpful later when you need to match drive letter assignments at System B. HP NetServer Installation Guide 32
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 39
    the Shutdown Computer prompt (with the option to Restart). 4. Leave the prompt displayed and the computer powered on. The computer is powered on but idle. HP NetServer Installation Guide 33
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 40
    letter that matches the System A drive letter and click OK. Disk Administrator updates the disk driver letter assignment and makes the assignment permanent. NOTE To make sure you are assigning drive letters arrays are now fully configured for use by the cluster. HP NetServer Installation Guide 34
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 41
    the Component CD of Microsoft Windows NT Server, Enterprise Edition in the CD-ROM drive of System B. 2. Run the Microsoft Cluster Server setup program Cluster Server software setup of System A. Click Next. Microsoft Cluster Administrator, Assigning a Cluster Name HP NetServer Installation Guide 35
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 42
    the right column are shared by both systems. Normally you would share all disks listed. Microsoft Cluster Server Setup, Assigning Shared Disks to the Cluster 8. Setup prompts you to select a disk (quorum adapter, and System A and B reside on the same IP subnet. HP NetServer Installation Guide 36
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 43
    IP Address already filled in. However, your configuration may display the Client LAN first. Microsoft Cluster Server Setup, Assigning a Network Name to the intra-cluster LAN 10. Repeat the previous step for has the highest priority. See the example dialog below. HP NetServer Installation Guide 37
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 44
    specifications and starts the cluster service. 15. Microsoft Cluster Server is now fully installed on System B. Reboot System B. 16. To finish installation of the Microsoft Cluster Server, leave System B running, go to the next procedure and install MSCS on System A. HP NetServer Installation Guide
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 45
    not already downloaded clusfixi.exe, see "Software" in part "1 What's Needed." 2. Install the Microsoft hotfix clusfixi.exe on System A and System B. NOTE When downloading the file, refer to the Microsoft readme file for instructions on installing the hotfix. HP NetServer Installation Guide 39
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 46
    on the HP NetServer Navigator CD-ROM. You can run the test directly from the CD, or you can create a bootable floppy disk from HP NetServer Navigator's disk library detailed information on the utility and instructions for setting up and running the utility. HP NetServer Installation Guide 40
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 47
    to download this program. Run CIT Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help. CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the program. HP NetServer Installation Guide 41
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 48
    NetRAID Supplement to HP NetServer Microsoft Cluster Installation Guide 8 March 1999
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 49
    and troubleshoots the Microsoft Cluster Server. Hewlett-Packard Company assumes this person is qualified to service computer equipment and trained to recognize hazards in products with hazardous energy levels. NOTE Hewlett-Packard only supports and recommends installation of clustered HP NetServer
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 50
    the HP NetServers Microsoft Cluster Installation Guide. VERSION HISTORY...2 1 WHAT'S NEEDED ...4 SOFTWARE...4 NEED MORE HELP?...4 OBTAIN HP NETRAID UTILITIES ...4 2 NETSERVER HARDWARE SETUP ...6 3 SHARED STORAGE HARDWARE SETUP 7 HP RACK STORAGE/12 SETUP...7 HP RACK STORAGE/8 SETUP ...8 HP STORAGE
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 51
    to unpack the archive. • Follow the instructions in the readme.txt file to create the installation floppy disk. Label the floppy disk NetRAID-3Si Cluster Firmware and Driver then go to part 2 "NetServer Hardware Setup." NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 4
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 52
    Floppy Disk NR Cluster Firmware and Driver HP NetRAID Assistant 1 HP NetRAID Assistant 2 7. Label three blank formatted floppy disks as listed. 8. Copy the contents of each subdirectory to the appropriate floppy disk. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 5
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 53
    PCI slots specified by the HP NetServer Configuration Guide for your cluster configuration. 2. Make sure that previously installed adapters are in the correct PCI slots. NOTE For clusters using HP NetRAID adapters, typically, only one is provided (installed) in the server for management of shared
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 54
    ) in each Rack Storage/12. Follow the instructions supplied with the Controller for installation. to part "4 Cluster Cabling and Setup" in the Installation Guide or setup another share storage device such as the Rack Storage/8. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 55
    option switches as shown below. Option Switches Set to Up Down %ULGJH &DEOH HP Rack Storage/8 Single Bus Configuration Connect the Bridge Cable Use the bridge cable included Cluster Cabling and Setup" in the Installation Guide NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 56
    Interior Before connecting the disks housed in the HP Storage System/6, set up the internal cables to support the cluster. To gain access proceed as chassis. HP Storage System/6 Cabinet with Bezel and Side Cover Removed NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 9
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 57
    Verify and Reconnect Internal Cabling Using the schematic view of the HP Storage System/6's internal cabling shown below, check and if necessary, reroute the three 5182-9326 Storage System/6 Cabinet Internal Cabling NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 10
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 58
    A or B at this time. You must configure the HP NetRAID Adapter and install Microsoft Windows NT Server, Enterprise Edition before attaching the shared storage unit. to part "4 Cluster Setup and Cabling" of the Installation Guide NetRAID Supplement to the HP NetServer Microsoft Cluster Installation
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 59
    not cross. That is, make sure to connect channel 0, 1, and 2 from one HP NetServers through the storage cabinet to channel 0, 1, and 2 respectively on the second HP NetServer. Follow the cabling diagram(s) in the configuration guide carefully. It is a good idea to number or color-code the cable ends
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 60
    5 NetServer Software Setup This part of the supplement is intentionally left blank. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 13
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 61
    the system. 3. The system will boot to DOS and run the HP NetRAID firmware flash utility. Follow the instructions to update the firmware on all NetRAID-3Si adapters. When complete, cycle power on the system to reboot. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 14
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 62
    it. HP NetRAID HP NetRAID Express Tools when all adapters have been configured. 9. Power down System A, power up System B, and repeat the procedures for System B starting at the beginning of this part (Update the Firmware). NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 63
    10. Exit HP NetRAID Express Tools when all adapters have been configured. 11. Power down System A, power up System B, and repeat the procedures for System B starting at the beginning of this part (Update the Firmware). NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 16
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 64
    system log during reboot. The entry is: Event ID: Source: Type: Description: 4 mraidnt Error Driver detect an internal error in its data structure for. This is a spurious event and may be ignored. No error occurred. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 17
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 65
    Server Software is fully installed after part "7 Microsoft Cluster Server Software Setup" in the Installation Guide, make sure that only one HP NetServer Software Setup" of the Installation Guide. Set RAID Levels on a Cluster Use these instructions to set up HP NetServer cluster RAID level 1, 5, 10
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 66
    for use. Out of service because a fault occurred. Rebuilding an array on a new drive. Refer to the HP NetRAID User Guide in Information Assistant for more information about HP NetRAID Assistant. Setup all data is still NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 19
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 67
    the dialog and click Next. The Configuration Wizard displays its Array Definition window. HP NetRAID Array Definition 3. In the Array Definition window define an array by selecting 3 and 4 to define identical arrays. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 20
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 68
    you have defined the cluster's arrays, initialize the arrays you defined. HP NetRAID Assistant initializes all arrays at the same time. To initialize the 2.1 Parity 2 Block 2.2 3 Parity 3 Block 3.1 Block 3.2 NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 21
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 69
    in the dialog and click Next. The Configuration Wizard displays its Array Definition window. HP NetRAID Array Definition 3. In the Array Definition window define an array by selecting the storage capacity for the NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide 22
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 70
    's arrays, initialize the arrays you defined. HP NetRAID Assistant initializes all arrays you have defined HP NetRAID Initialization may be time consuming. 2. When initialization is complete, exit HP NetRAID Assistant. NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 71
    Attachment A to HP NetServer Microsoft Cluster Installation Guide "Using the NetRAID Adapter for LCII or LC3 Local Storage" 17 March 1999
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 72
    This attachment is incomplete without the HP NetServers Microsoft Cluster Installation Guide. When prompted return to the Installation Guide to get the necessary instructions. VERSION HISTORY ...3 AN OVERVIEW ...3 1 - WHAT'S NEEDED...3 2 - NETSERVER HARDWARE SETUP ...3 3 - SHARED STORAGE HARDWARE
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 73
    Needed • If not already available, obtain HP NetRAID Utilities (driver, firmware, and NetRAID Assistant). See HP NetServer Installation Guide for instructions. • Windows NT boot floppies. Make a set of Windows NT boot floppies from the Windows NT Server/E base CD. On a computer running Windows 95 or
  • HP LH4r | HP Netserver LC 3 NetRAID Installation Guide - Page 74
    a "NOS Drivers" Disk While running HP NetServer Navigator in the Installation Guide and before leaving the "Configure NetServer Hardware and BIOS" procedure, make a drivers disk from the Navigator CD as follows: 1. From the Navigator main menu select, NetServer Utilities | More NetServer Utilities
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Microsoft Cluster Installation
Documentation
To assist you in installing your HP NetServer Microsoft Cluster, this file contains the
separate documents listed below combined into one pdf file.
Configuration Guide
- This guide provides configuration information specific to your
cluster configuration that you will need during the installation of your cluster.
HP NetServer Microsoft Cluster Installation Guide
- This is the first of two
documents used to install the cluster.
It covers the installation of all cluster supported
HP NetServers and the cluster software, and references the Shared Storage Supplement
for installation and setup of the shared storage.
Shared Storage Supplement
- This supplement is specific to the shared storage device
you are using and must be used with the installation guide.
It provides instructions for
installing and setting up your shared storage devices.
Attachment A
- This attachment describes installation of a NetRAID adapter for local
storage.
17 March 1999
(See next page)