HP LH4r HP Netserver Remote Administrator Guide - Page 81
A Event Codes, manage\server.
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
A Event Codes The table below describes the event codes that can be sent via pager or listed in the event log. When Integrated RA sends a page about a server event, it includes the server identifying number and a five-digit code identifying the event. (If you have a TAP pager, you will receive the server name and some descriptive text as well.) Note that NetServer Agents software will need to be loaded on your server in order to receive an event notification for most of the events listed below. Refer to the HP NetServer SNMP agents documentation (viewable via the NetServer Documentation CD) for agent installation and configuration instructions. Refer to the Readme file for Agents software located on the Navigator CD under manage\server. NOTE It's a good idea to copy appropriate sections of this table and keep it with the pager you use to receive notifications. A regularly updated list of HP supported event codes is available via the WWW at http://www.hp.com/netserver under the Troubleshooting section under Technical Support. Notification and log messages are limited to a length of 40 characters. Pager Code Server Event 001XX Temperature sensor crossed lower non-critical threshold 001XX Temperature sensor crossed lower critical threshold 001XX Temperature sensor crossed lower non-recoverable threshold 001XX A temperature inside the server has gone outside the factory specified range. 001XX A temperature inside the server has gone far outside the factory specified range. 001XX Temperature sensor crossed upper non-recoverable threshold 002XX A measured voltage in the server has gone outside the factory specified lower voltage range. 002XX A measured voltage in the server has gone far outside the factory specified lower voltage range. 002XX Voltage sensor crossed lower non-recoverable threshold 002XX A measured voltage in the server has gone outside the factory specified upper voltage range. 002XX A measured voltage in the server has gone far outside the factory specified upper voltage range. 002XX Voltage sensor crossed upper non-recoverable threshold 002XX System Voltage failure 004XX A fan sensor in the server has gone outside the factory specified Severity WARNING CRITICAL CRITICAL WARNING CRITICAL CRITICAL WARNING CRITICAL CRITICAL WARNING CRITICAL CRITICAL WARNING WARNING 77