r Code Server Event, Severity, Power Supply Subsystem: Not enough Power Supply Units detected.
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
Appendix A Event Codes Pager Code Server Event 00823 A power supply's 3.3 volt supply has gone bad. 00824 A power supply's 5 volt supply has gone bad. 00825 A power supply's 12 volt supply has gone bad. 00826 A power supply's -12 volt supply has gone bad. 00900 Power supply subsystem redundancy gained. 00901 Power supply subsystem redundancy lost. 00902 Power Supply Subsystem: Not enough Power Supply Units detected. 00904 Power System failure A/C Lost 00905 Power Supply Subsystem soft failure 00906 Power Supply Subsystem: Not enough Power Supply Units detected or trouble powering up or down. 01070 Multiple Fan Failure 01107 Battery cycles have gone beyond the upper non-critical range 01109 Battery cycles have gone beyond the upper critical range 01111 Battery cycles have gone beyond the upper non-recoverable range 01200 A single-bit error has been corrected 01201 Predictive failure in a memory module 01201 Multiple-bit error has occurred 01202 Parity error detected in parity memory 01203 Single-bit repeated error 01300 Hot swap Cage: Drive removed 01301 Hot swap Cage: Drive inserted 01320 Hot swap disks: Power connection failure 01321 Hot swap disks: Temperature emergency 01322 Hot swap disks: Temperature warning 01323 Hot swap disks: Temperature monitor not working 01400 System memory size reduced due to error in memory slot 01520 Post error has occurred 01600 Too many single-bit errors in time period, logging disabled 01601 Too many errors of this type in time period 01602 Event log cleared. 01620 Event log getting full. 01700 Automatic Server Restart: hard reset after NOS hang 01701 Automatic Server Restart: hard reset after NOS hang 01702 OS Watchdog Shutdown 01703 Automatic Server Restart: power down after NOS hang 01704 Automatic Server Restart: power cycle after NOS hang 01705 OS Watchdog poweroff 01706 NOS hang, automatic server restart disabled 01800 System configuration altered by EISA utility 01801 Server booted and power on self tests completed. 01900 NOS memory dump initiated 01901 One of the bus masters caused a bus timeout 01902 I/0 channel check caused an error 01903 Software NMI has been generated 01904 PCI bus error 01905 PCI system error 01906 Failsafe timer has timed out 01907 Correctable data error Severity CRITICAL CRITICAL CRITICAL CRITICAL INFORMATIONAL WARNING CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL WARNING CRITICAL CRITICAL INFORMATIONAL WARNING CRITICAL CRITICAL INFORMATIONAL CRITICAL INFORMATIONAL CRITICAL CRITICAL WARNING CRITICAL WARNING WARNING CRITICAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL INFORMATIONAL CRITICAL INFORMATIONAL INFORMATIONAL CRITICAL INFORMATIONAL INFORMATIONAL INFORMATIONAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL INFORMATIONAL 79