Appendix A, Event Codes, r Code Server Event, Severity, 004XX
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Appendix A Event Codes Pager Code Server Event range. 004XX A fan sensor in the server has gone far outside the factory specified range. 004XX Fan sensor crossed lower non-recoverable threshold 004XX Fan sensor crossed upper non-critical threshold 004XX Fan sensor crossed upper critical threshold 004XX Fan sensor crossed upper non-recoverable threshold 004XX Two or more of the fans in the Processor/PCI Fan Tray have stopped or have been removed. 004XX Fan problem in Processor/PCI Fan Tray has been corrected. 004XX Two or more of the fans in the Memory Fan Tray have stopped or been removed. 004XX Fan problem in the Memory Fan Tray has been corrected. 004XX One of the fans in the Memory Fan Tray stopped. 004XX One of the fans in the Processor/PCI fan tray stopped. 00520 I/O area open 00530 The server's built-in sensors have detected an open chassis door. 00530 Processor area open 00600 Front Panel Button Violation 00701 Processor module is operating outside of acceptable margins 00700 Processor internal error 00701 Processor Thermal Trip Failure 00702 Processor failed internal self test 00703 Processor hung during POST 00704 Processor startup/initialization failed 00705 Configuration Error in a Processor Slot 00707 Processor failure 00708 Processor (#) Disabled 00709 Processor or Terminator was not detected 00717 Processor problem 00718 The Processor in the indicated slot has been disabled by the BIOS. 00719 A single or multiple ECC Error has been detected on the P6 bus. 00720 The Processor Card is missing or not properly terminated in indicated processor module. 00721 Voltage Regulating Module (VRM) on the indicated processor module had failed. 00800 Indicated Power Supply has been removed. 00800 The indicated Power Supply has been inserted. 00801 Power supply unit power has failed. 00802 Predictive failure/alert in Power supply 00816 Redundant Power Supply: Subsystem warning temperature exceeded 00817 Temperature alert on designated Power Supply. 00818 Redundant Power Supply: AC power source failure 00819 Redundant Power Supply: Protection temperature exceeded, DC shutdown 00820 Redundant Power Supply: Protection temperature normal, power restored 00821 Fan failure on designated Power Supply. 00822 Fan speed-up on designated Power Supply. Severity CRITICAL CRITICAL WARNING CRITICAL CRITICAL CRITICAL INFORMATIONAL CRITICAL INFORMATIONAL CRITICAL CRITICAL WARNING WARNING WARNING INFORMATIONAL WARNING CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL CRITICAL WARNING WARNING CRITICAL WARNING INFORMATIONAL WARNING WARNING WARNING CRITICAL CRITICAL CRITICAL INFORMATIONAL CRITICAL WARNING 78