HP Pro 2080 Maintenance & Service Guide: HP Pro 2000/2080 Business PC - Page 122

Appendix D, Specifications, For 115V/60Mhz, 250W PFC+ HV, 300W 85% EFF, For 230V/50Hz, Power Supply

Page 122 highlights

Table D-1 Specifications (continued) Typical (idle) For 115V/60Mhz For 230V/50Hz 250W PFC+ HV: 250W PFC+ HV ATX: 53.1W or 181.177 BTU/hr or 45.657Kg-cal/hr 49.8 W or 169.918 BTU/hr or 42.819Kg-cal/hr 300W PFC+ HV: 300W PFC+ HV: 55.1W or 188.001 BTU/hr or 47.376Kg-cal/hr 54.5W or 185.954 BTU/hr or 46.86Kg-cal/hr 300W 85% EFF: 300W 85% EFF: 46.4W or 158.317BTU/hr or 39.896Kg-cal/hr 45.77W or 156.167 BTU/hr or 39.354Kg-cal/hr Power Supply 115V 230V Operating Voltage Range 90-132 VAC 180-264 VAC Rated Voltage Range 100-127 VAC 200-240 VAC Rated Line Frequency 50-60 Hz 50-60 Hz Power Output 300 W 300 W Rated Input Current (maximum)1 8A @ 100 VAC 4A @ 200 VAC 1 This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European Union. This supply requires the use of an input voltage range select switch. 114 Appendix D Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125

Typical (idle)
For 115V/60Mhz
250W PFC+ HV:
53.1W or 181.177 BTU/hr or
45.657Kg-cal/hr
300W PFC+ HV:
55.1W or 188.001 BTU/hr or
47.376Kg-cal/hr
300W 85% EFF:
46.4W or 158.317BTU/hr or
39.896Kg-cal/hr
For 230V/50Hz
250W PFC+ HV ATX:
49.8 W or 169.918 BTU/hr or
42.819Kg-cal/hr
300W PFC+ HV:
54.5W or 185.954 BTU/hr or
46.86Kg-cal/hr
300W 85% EFF:
45.77W or 156.167 BTU/hr or
39.354Kg-cal/hr
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
115V
90-132 VAC
100-127 VAC
50-60 Hz
230V
180-264 VAC
200-240 VAC
50-60 Hz
Power Output
300 W
300 W
Rated Input Current (maximum)
1
8A @ 100 VAC
4A @ 200 VAC
1
This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V
operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European
Union. This supply requires the use of an input voltage range select switch.
Table D-1
Specifications (continued)
114
Appendix D
Specifications