HP StorageWorks 2/140 FW 08.01.00 McDATA E/OS SNMP Support Manual (620-000131- - Page 183
fcConnUnitProxyMaster, fcConnUnitPrincipal, fcConnUnitNumSensors
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 183 highlights
Fibre Alliance MIB A Max-Access Status Description Sequence read-only current 24 bit Fibre Channel address ID of this connectivity unit. Following the fibre channel standard, the right-most bit of the right-most octet is for the least significant bit of the address value; the left-most bit of the left-most octet, if needed, is for the most significant bit of the address value. If this value is not applicable, all bits set to 1. ::= { fcConnUnitEntry 11 } fcConnUnitProxyMaster Syntax Max-Access Status Description Sequence INTEGER { unknown(1), no(2), yes(3) } read-only current A value of 'yes' means this is the proxy master unit for a set of managed units. For example, this could be the only unit with a management card in it for a set of units. A standalone unit should return 'yes' for this object. ::= { fcConnUnitEntry 12 } fcConnUnitPrincipal Syntax Max-Access Status Description Sequence INTEGER {unknown(1), no(2), yes(3) } read-only current Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, return unknown. ::= { fcConnUnitEntry 13 } fcConnUnitNumSensors Syntax Max-Access Status Description Unsigned32 read-only current Number of sensors in the fcConnUnitSensorTable. FA MIB A-13