HP StorageWorks 2/140 FW 08.01.00 McDATA E/OS SNMP Support Manual (620-000131- - Page 185
fcConnUnitInfo, fcConnUnitControl
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 185 highlights
Fibre Alliance MIB A fcConnUnitInfo Syntax Max-Access Status Description Sequence SnmpAdminString read-write current Information about this connectivity unit. This object value should be persistent between boots. ::= { fcConnUnitEntry 18 } fcConnUnitControl Syntax Max-Access Status Description INTEGER { unknown(1), invalid(2), resetConnUnitColdStart(3), resetConnUnitWarmStart(4), offlineConnUnit(5), onlineConnUnit(6) } read-write current This object is used to control the addressed connectivity unit. NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2 and are not meant to be a factory reset. resetConnUnitColdStart: the addressed unit performs a 'ColdStart' reset. FA MIB A-15
A
FA MIB
A-15
Fibre Alliance MIB
fcConnUnitInfo
Syntax
SnmpAdminString
Max-Access
read-write
Status
current
Description
Information about this connectivity unit. This object value should be
persistent between boots.
Sequence
::= { fcConnUnitEntry 18 }
fcConnUnitControl
Syntax
INTEGER {
unknown(1),
invalid(2),
resetConnUnitColdStart(3),
resetConnUnitWarmStart(4),
offlineConnUnit(5),
onlineConnUnit(6) }
Max-Access
read-write
Status
current
Description
This object is used to control the addressed connectivity unit.
NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2 and are
not meant to be a factory reset.
resetConnUnitColdStart:
the addressed unit performs a 'ColdStart'
reset.