HP StorageWorks 64 FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manua - Page 497
fcFxPortCapBbCreditMax, fcFxPortCapRxDataFieldSizeMax, connect-request
View all HP StorageWorks 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 497 highlights
Fabric Element Management MIB F fcFxPortCapBbCreditMax Syntax FcBbCredit Access read-only Status mandatory Description The maximum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached NxPort. Sequence ::= { fcFxPortCapEntry 5 } fcFxPortCapBbCreditMin Syntax FcBbCredit Access read-only Status mandatory Description The minimum number of receive buffers available for holding Class 1 connect-request, Class 2 or Class 3 frames from the attached NxPort. Sequence ::= { fcFxPortCapEntry 6 } fcFxPortCapRxDataFieldSizeMax Syntax FcRxDataFieldSize Access read-only Status mandatory Description The maximum size in bytes of the Data Field in a frame that the FxPort is capable of receiving from its attached NxPort. Sequence ::= { fcFxPortCapEntry 7 } fcFxPortCapRxDataFieldSizeMin Syntax FcRxDataFieldSize Access read-only Status mandatory Description The minimum size in bytes of the Data Field in a frame that the FxPort is capable of receiving from its attached NxPort. FCFE.MIB F-49