Honeywell VISTAKEY User Guide - Page 13

Table 1: Action Codes

Page 13 highlights

User Commands (cont'd) Table 1: Action Codes ACTION ACTION NO. NAME ACTION ACTION SPECIFIER DESCRIPTION Relay Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for relay commands. "During" can be used to control the relay for a specific time only. For example, if "during" is selected with Relay On, the system will automatically energize the relay at the beginning of the window and automatically de-energize the relay at the end of the window. 01 Relay On Relay # Relay On - Turn on relay indicated by the specifier 02 Relay Off Relay # Relay Off - Turn off relay indicated by the specifier 03 Rly On 2 Sec Relay # Relay Close for 2 seconds - Close relay indicated by the specifier for 2 seconds 04 Relay xx Min Relay # Relay Close XX minutes - Close relay indicated by the specifier for XX minutes (the XX value was set by the system installer) 05 Relay yy Relay # Relay Close YY seconds - Close relay indicated by specifier for Sec YY seconds (the YY value was set by the system installer) 06 Rly Grp On Relay Group Relay Group On - Turn on relay group indicated by specifier # 07 Rly Grp Off Relay Group Relay Group Off - Turn off relay group indicated by the specifier # 08 Rly Grp 2 Relay Group Relay Group Close for 2 seconds - Close all relays in the group Sec # indicated by the specifier for 2 seconds 09 Rly Grp xx Relay Group Relay Group Close XX minutes - Close relay group indicated by Min # the specifier for XX minutes (the XX value was set by the system installer) 10 Rly Grp yy Relay Group Relay Group Close YY seconds - Close relay group indicated by Sec # the specifier for YY seconds (the YY value was set by the system installer) Arm/Disarm Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for automatic arming and disarming functions. "During" can be used to arm or disarm the control for a specific time only. For example, if "during" is selected with ArmSTAY, the system will automatically Arm-STAY at the beginning of the window and automatically disarm at the end of the window. 20 Arm STAY Partition(s) Arm STAY - Arm the partition(s) indicated by the specifier in the STAY mode 21 Arm AWAY Partition(s) Arm AWAY - Arm the partition(s) indicated by the specifier in the AWAY mode 22 Disarm Partition(s) Disarm - Disarm the partition(s) indicated by the specifier 23 Force Arm Partition(s) Force Arm STAY - Force arm the partition(s) indicated by STAY specifier in the STAY mode (Auto-bypass faulted zones) 24 Force Arm Partition(s) Force Arm AWAY - Force arm the partition(s) indicated by the AWAY specifier in the AWAY mode (auto-bypass faulted zones) - 13 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

User Commands (cont’d)
– 13 –
Table 1: Action Codes
ACTION
NO.
ACTION
NAME
ACTION
SPECIFIER
ACTION
DESCRIPTION
Relay Commands
Activation times
1
(Beginning),
2
(End),
3
(During) are the only valid choices for relay commands.
“During” can be used to control the relay for a specific time only. For example, if “during” is selected with Relay On, the
system will automatically energize the relay at the beginning of the window and automatically de-energize the relay at
the end of the window.
01
Relay On
Relay #
Relay On – Turn on relay indicated by the specifier
02
Relay Off
Relay #
Relay Off – Turn off relay indicated by the specifier
03
Rly On 2 Sec
Relay #
Relay Close for 2 seconds – Close relay indicated by the
specifier for 2 seconds
04
Relay xx Min
Relay #
Relay Close XX minutes – Close relay indicated by the specifier
for XX minutes (the XX value was set by the system installer)
05
Relay
yy
Sec
Relay #
Relay Close YY seconds – Close relay indicated by specifier for
YY seconds (the YY value was set by the system installer)
06
Rly Grp On
Relay Group
#
Relay Group On – Turn on relay group indicated by specifier
07
Rly Grp Off
Relay Group
#
Relay Group Off – Turn off relay group indicated by the specifier
08
Rly Grp 2
Sec
Relay Group
#
Relay Group Close for 2 seconds – Close all relays in the group
indicated by the specifier for 2 seconds
09
Rly Grp xx
Min
Relay Group
#
Relay Group Close XX minutes – Close relay group indicated by
the specifier for XX minutes (the XX value was set by the system
installer)
10
Rly Grp yy
Sec
Relay Group
#
Relay Group Close YY seconds – Close relay group indicated by
the specifier for YY seconds (the YY value was set by the
system installer)
Arm/Disarm Commands
Activation times
1
(Beginning),
2
(End),
3
(During) are the only valid choices for automatic arming and disarming
functions.
“During” can be used to arm or disarm the control for a specific time only. For example, if “during” is selected with Arm-
STAY, the system will automatically Arm-STAY at the beginning of the window and automatically disarm at the end of
the window.
20
Arm STAY
Partition(s)
Arm STAY – Arm the partition(s) indicated by the specifier in the
STAY mode
21
Arm AWAY
Partition(s)
Arm AWAY – Arm the partition(s) indicated by the specifier in
the AWAY mode
22
Disarm
Partition(s)
Disarm – Disarm the partition(s) indicated by the specifier
23
Force Arm
STAY
Partition(s)
Force Arm STAY – Force arm the partition(s) indicated by
specifier in the STAY mode (Auto-bypass faulted zones)
24
Force Arm
AWAY
Partition(s)
Force Arm AWAY – Force arm the partition(s) indicated by the
specifier in the AWAY mode (auto-bypass faulted zones)