Table 1: Action Codes cont'd

Page 14 highlights

User Commands (cont'd) Table 1: Action Codes (cont'd) ACTION ACTION NO. NAME ACTION ACTION SPECIFIER DESCRIPTION Bypass Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for bypass commands. If 3 (During) is selected for auto-bypassing, the system bypasses the zone(s) specified on a particular zone list at the beginning of the window and unbypasses the zone(s) at the end of the window. If it is selected for auto unbypassing, the system removes the bypass of the zone(s) at the beginning of the window and restores the bypass at the end of the window. 30 Bypass Zn Zone list # Auto bypass zone list - Automatically bypass the zone list List indicated by the specifier 31 Unbyps Zn Zone list # Auto unbypass zone list - Automatically unbypass the zone list List indicated by the specifier Open/Close Windows Activation time 3 (During) is the only valid choice for these commands. When using Enable Open Window, Enable Close Window, and Enable Access Window, the window is active for the partitions selected by the specifier except as follows: • When an Event/Action occurs that would disable a window (partition not selected), the window for the partition is only disabled if it is not currently enabled by a timed method (e.g., O/C schedule, Time-Driven Event, Access Schedule). • When a timed window (e.g., O/C schedule, Time-Driven Event, Access Schedule) occurs that would disable a window (partition not selected), the window for the partition is only disabled if it is not currently enabled by an Event/Action. 40 En Open Partition(s) Enable Opening Window by partition - Enable the opening Wind window for the partition indicated by the specifier 41 En Close Partition(s) Enable Closing Window by partition - Enable the closing window Wind for the partition indicated by the specifier 42 En Access Access Enable Access Window for access group - Enable the access Wind Group window for the access group indicated by the specifier (enables user arming or disarming) 50 Off-Normal None Off-Normal Reminder - Starts local keypad beeping if fire off- Reminder normal condition exists Access Related Actions All access-related actions are active during the time window and you are not presented with a prompt requesting an activation time. 55 AP Grant Access Point Access Point Grant - Grant access at access point indicated by # specifier 56 AP Grant/O Access Point Access Point Grant with Override - Grant access with override # at access point indicated by specifier 57 AP Protect Access Point Access Point Protect - Protect access point indicated by # specifier 58 AP Bypass Access Point Access Point Bypass - Bypass access point indicated by # specifier 59 AP Lock Access Point Access Point Lock - Lock access point indicated by specifier # 60 AP Exit Only Access Point Access Point Exit Only - Put access point indicated by specifier # in Exit Only mode - 14 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

User Commands (cont’d)
– 14 –
Table 1: Action Codes (cont’d)
ACTION
NO.
ACTION
NAME
ACTION
SPECIFIER
ACTION
DESCRIPTION
Bypass Commands
Activation times
1
(Beginning),
2
(End),
3
(During) are the only valid choices for bypass commands. If
3
(During) is
selected for auto-bypassing, the system bypasses the zone(s) specified on a particular zone list at the beginning of the
window and unbypasses the zone(s) at the end of the window. If it is selected for auto unbypassing, the system
removes the bypass of the zone(s) at the beginning of the window and restores the bypass at the end of the window.
30
Bypass Zn
List
Zone list #
Auto bypass zone list – Automatically bypass the zone list
indicated by the specifier
31
Unbyps Zn
List
Zone list #
Auto unbypass zone list – Automatically unbypass the zone list
indicated by the specifier
Open/Close Windows
Activation time
3
(During) is the only valid choice for these commands. When using Enable Open Window, Enable
Close Window, and Enable Access Window, the window is active for the partitions selected by the specifier except as
follows:
When an Event/Action occurs that would disable a window (partition not selected), the window for the partition is only
disabled if it is not currently enabled by a timed method (e.g., O/C schedule, Time-Driven Event, Access Schedule).
When a timed window (e.g., O/C schedule, Time-Driven Event, Access Schedule) occurs that would disable a window
(partition not selected), the window for the partition is only disabled if it is not currently enabled by an Event/Action.
40
En Open
Wind
Partition(s)
Enable Opening Window by partition – Enable the opening
window for the partition indicated by the specifier
41
En Close
Wind
Partition(s)
Enable Closing Window by partition – Enable the closing window
for the partition indicated by the specifier
42
En Access
Wind
Access
Group
Enable Access Window for access group – Enable the access
window for the access group indicated by the specifier (enables
user arming or disarming)
50
Off-Normal
Reminder
None
Off-Normal Reminder – Starts local keypad beeping if fire off-
normal condition exists
Access Related Actions
All access-related actions are active during the time window and you are not presented with a prompt requesting an
activation time.
55
AP Grant
Access Point
#
Access Point Grant – Grant access at access point indicated by
specifier
56
AP Grant/O
Access Point
#
Access Point Grant with Override – Grant access with override
at access point indicated by specifier
57
AP Protect
Access Point
#
Access Point Protect – Protect access point indicated by
specifier
58
AP Bypass
Access Point
#
Access Point Bypass – Bypass access point indicated by
specifier
59
AP Lock
Access Point
#
Access Point Lock – Lock access point indicated by specifier
60
AP Exit Only
Access Point
#
Access Point Exit Only – Put access point
indicated by specifier
in Exit Only mode