Error Code/Symptom 020-XXX-004 (Failed Hot-Swap Slot 4 PCI Latch test) 030-XXX-000 (Failed Internal SCSI interface test) 035-XXX-000 DUPLICATE ERROR CODE (Failed System Board RAID test. Check System Error Log before replacing a FRU.) 035-XXX-000 DUPLICATE ERROR CODE (Check System Error Log before replacing a FRU.) 035-XXX-0NN (Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) 035-XXX-100 DUPLICATE ERROR CODE (Failed RAID test on PCI slot 1. Check System Error Log before replacing a FRU.) 035-XXX-100 DUPLICATE ERROR CODE (Check System Error Log before replacing a FRU.) 035-XXX-1NN (Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) 035-XXX-200 DUPLICATE ERROR CODE (Failed RAID test on PCI slot 2. Check System Error Log before replacing a FRU.) 035-XXX-200 DUPLICATE ERROR CODE (Check System Error Log before replacing a FRU.) 035-XXX-2NN (Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.) FRU/Action 1. PCI Hot-Swap Latch Assembly 2. System Board 1. System Board 1. Verify RAID adapter disable jumper block is not installed (see "System board jumpers" on page 280). 2. System Board 3. SCSI Backplane 4. Cable 1. Fixed Disk with SCSI ID 00 on System Board RAID controller 1. Fixed Disk with SCSI ID NN on System Board RAID controller 1. Adapter 2. SCSI Backplane 3. Cable 1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 1 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 1 1. Adapter 2. SCSI Backplane 3. Cable 1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 2 1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 2 294 Netfinity Server HMM
![](/manual_guide/products/ibm-86625ry-hardware-maintenance-manual-7f818c4/302.png)